11
ZPA-6240TU
Ordercode: D6180
Fig. 03
USB connector B
Connect the device to a PC, in order to carry out the necessary updates.
Message control connector
Designed to control the digital messages of the host. If you do not possess our PM-Six
(D6182)
microphone system, you can still create a trigger button system, in order to control the messages.
See the chart below for more information about connecting the trigger buttons.
Remote power switch terminal connector
Connect a remote button, by means of which it is possible to remotely switch the device ON/OFF.
24V DC terminal connector – IN
This input can be used in mobile applications, such as boats, where 120 or 230V AC is not available
or in applications that must continue to operate in case of power shortage. When a 24V DC battery
is connected, the unit will operate on the supplied DC voltage. The amplifier has a built-in charger,
which charges the connected battery.
IEC power connector 230V AC
Connect the device to the appropriate power supply.
Ground/earth connection