8
AS-8
Ordercode: D1904
Set Up and Operation
Follow the directions below, as they pertain to your preferred operation mode.
Before plugging the unit in, always make sure that the power supply matches the product specification
voltage. Do not attempt to operate a 115V specification product on 230V power, or vice versa.
Fig. 04
MAIN Section
01)
By means of the
Main Input Level control
(01)
, both main inputs interface with the input bus and the
main outputs.
02)
Set the output level of the signals, summed by the second bus, by turning the
Main Output Level
control (03)
. The signals will then be sent to the main outputs.
Splitter Mode
01)
The main input signal is processed by the
Balance control (06)
to the output buffer mono channels’
amplifiers.
02)
Turn the
Level control (04)
to set the output level of the respective channel.
Mixer Mode
01)
The input signals are compiled through the
Level control (04)
and the
Pan control (06)
. Subsequently,
they are sent to the output bus.
02)
Turn the
Level control (04)
to set the amount of each channel at the output bus.
03)
Turn the
Pan control (06)
to allocate the input signal to the left/right main outputs.
04)
The input signal is routed to the appropriate mono outputs. The circuit functions as a matching
amplifier. Turn the
Level control (04)
to set level compensation.
Summary of Contents for AS-8