— 38 —
Each individual HD channel presentation echoes the primary
program-associated data provided on the
Listener Experience
page, but in addition flags whether
Logo
and
Artist Experience
information is being received,
and gives additional statistical information
for HD Radio images.
Image Data
are shown as-received in a rolling real-time plot of
the most recent data packets. The time period automatically
varies with the data as the plot is capable of displaying only a
certain number of events.
A further refinement of
Image Data
in tabular form appears be-
low the rolling graphic. The tabulation assigns absolute values
to
Type
,
Packet Size
,
Segment
#
and
Time
. This tabulation ‘rolls’
as well, showing the same events as the timeline graphic. In-
formation includes the times that images are received and
cleared, and verifies the repeat interval. You may ‘drill down’
through several minutes of this information that is useful in
troubleshooting HD Radio image display problems.
ALARMS
Alarm Status
The 552 provides alarms for a total of 20 signal or program-
related error conditions.
Alarm Status
indicator ‘lamps’ head the
Alarms
Webpage, and also appear on the
Now Playing
Webpage.
Set the Clock!
Alarms are logged with time and duration stamps. Be sure to
select the time zone and ensure that the 552 is sync’d with In-
ternet time. This is explained shortly.