9-52
Fault Situation Counter
0 N/A
All set-ups
TRUE
0
Uint16
9-53
Profibus Warning Word
0 N/A
All set-ups
TRUE
0
V2
9-63
Actual Baud Rate
[255] No baudrate
found
All set-ups
TRUE
–
Uint8
9-64
Device Identification
0 N/A
All set-ups
TRUE
0
Uint16
9-65
Profile Number
0 N/A
All set-ups
TRUE
0
OctStr[2]
9-67
Control Word 1
0 N/A
All set-ups
TRUE
0
V2
9-68
Status Word 1
0 N/A
All set-ups
TRUE
0
V2
9-70
Edit Set-up
[1] Set-up 1
All set-ups
TRUE
–
Uint8
9-71
Profibus Save Data Values
[0] Off
All set-ups
TRUE
–
Uint8
9-72
ProfibusDriveReset
[0] No action
1 set-up
FALSE
–
Uint8
9-75
DO Identification
0 N/A
All set-ups
TRUE
0
Uint16
9-80
Defined Parameters (1)
0 N/A
All set-ups
FALSE
0
Uint16
9-81
Defined Parameters (2)
0 N/A
All set-ups
FALSE
0
Uint16
9-82
Defined Parameters (3)
0 N/A
All set-ups
FALSE
0
Uint16
9-83
Defined Parameters (4)
0 N/A
All set-ups
FALSE
0
Uint16
9-84
Defined Parameters (5)
0 N/A
All set-ups
FALSE
0
Uint16
9-85
Defined Parameters (6)
0 N/A
All set-ups
FALSE
0
Uint16
9-90
Changed Parameters (1)
0 N/A
All set-ups
FALSE
0
Uint16
9-91
Changed Parameters (2)
0 N/A
All set-ups
FALSE
0
Uint16
9-92
Changed Parameters (3)
0 N/A
All set-ups
FALSE
0
Uint16
9-93
Changed Parameters (4)
0 N/A
All set-ups
FALSE
0
Uint16
9-94
Changed Parameters (5)
0 N/A
All set-ups
FALSE
0
Uint16
9-99
Profibus Revision Counter
0 N/A
All set-ups
TRUE
0
Uint16
5.3.11 13-** Smart Logic
Par-
ameter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
13-0* SLC Settings
13-00
SL Controller Mode
ExpressionLimit
2 set-ups
TRUE
–
Uint8
13-01
Start Event
ExpressionLimit
2 set-ups
TRUE
–
Uint8
13-02
Stop Event
ExpressionLimit
2 set-ups
TRUE
–
Uint8
13-03
Reset SLC
[0] Do not reset
SLC
All set-ups
TRUE
–
Uint8
13-1* Comparators
13-10
Comparator Operand
ExpressionLimit
2 set-ups
TRUE
–
Uint8
13-11
Comparator Operator
ExpressionLimit
2 set-ups
TRUE
–
Uint8
13-12
Comparator Value
ExpressionLimit
2 set-ups
TRUE
-3
Int32
13-1* RS Flip Flops
13-15
RS-FF Operand S
ExpressionLimit
2 set-ups
TRUE
–
Uint8
13-16
RS-FF Operand R
ExpressionLimit
2 set-ups
TRUE
–
Uint8
13-2* Timers
13-20
SL Controller Timer
ExpressionLimit
1 set-up
TRUE
-3
TimD
13-4* Logic Rules
13-40
Logic Rule Boolean 1
ExpressionLimit
2 set-ups
TRUE
–
Uint8
13-41
Logic Rule Operator 1
ExpressionLimit
2 set-ups
TRUE
–
Uint8
13-42
Logic Rule Boolean 2
ExpressionLimit
2 set-ups
TRUE
–
Uint8
13-43
Logic Rule Operator 2
ExpressionLimit
2 set-ups
TRUE
–
Uint8
13-44
Logic Rule Boolean 3
ExpressionLimit
2 set-ups
TRUE
–
Uint8
13-5* States
13-51
SL Controller Event
ExpressionLimit
2 set-ups
TRUE
–
Uint8
13-52
SL Controller Action
ExpressionLimit
2 set-ups
TRUE
–
Uint8
Programming
Operating Guide
MG04F402