8-19
Product Code
ExpressionLimit
1 set-up
TRUE
0
Uint32
8-3* FC Port Settings
8-30
Protocol
[0] FC
1 set-up
TRUE
–
Uint8
8-31
Address
1 N/A
1 set-up
TRUE
0
Uint8
8-32
FC Port Baud Rate
ExpressionLimit
1 set-up
TRUE
–
Uint8
8-33
Parity / Stop Bits
[0] Even Parity, 1
Stop Bit
1 set-up
TRUE
–
Uint8
8-34
Estimated cycle time
0 ms
2 set-ups
TRUE
-3
Uint32
8-35
Minimum Response Delay
10 ms
1 set-up
TRUE
-3
Uint16
8-36
Max Response Delay
ExpressionLimit
1 set-up
TRUE
-3
Uint16
8-37
Max Inter-Char Delay
ExpressionLimit
1 set-up
TRUE
-5
Uint16
8-4* FC MC protocol set
8-40
Telegram Selection
[1] Standard
telegram 1
2 set-ups
TRUE
–
Uint8
8-41
Parameters for Signals
0
All set-ups
FALSE
–
Uint16
8-42
PCD Write Configuration
ExpressionLimit
2 set-ups
TRUE
0
Uint16
8-43
PCD Read Configuration
ExpressionLimit
2 set-ups
TRUE
0
Uint16
8-5* Digital/Bus
8-50
Coasting Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-51
Quick Stop Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-52
DC Brake Select
ExpressionLimit
All set-ups
TRUE
–
Uint8
8-53
Start Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-54
Reversing Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-55
Set-up Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-56
Preset Reference Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-57
Profidrive OFF2 Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-58
Profidrive OFF3 Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-8* FC Port Diagnostics
8-80
Bus Message Count
0 N/A
All set-ups
TRUE
0
Uint32
8-81
Bus Error Count
0 N/A
All set-ups
TRUE
0
Uint32
8-82
Slave Messages Rcvd
0 N/A
All set-ups
TRUE
0
Uint32
8-83
Slave Error Count
0 N/A
All set-ups
TRUE
0
Uint32
8-9* Bus Jog
8-90
Bus Jog 1 Speed
100 RPM
All set-ups
TRUE
67
Uint16
8-91
Bus Jog 2 Speed
ExpressionLimit
All set-ups
TRUE
67
Uint16
5.3.10 9-** Profibus
Par-
ameter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
9-00
Setpoint
0 N/A
All set-ups
TRUE
0
Uint16
9-07
Actual Value
0 N/A
All set-ups
FALSE
0
Uint16
9-15
PCD Write Configuration
ExpressionLimit
1 set-up
TRUE
–
Uint16
9-16
PCD Read Configuration
ExpressionLimit
2 set-ups
TRUE
–
Uint16
9-18
Node Address
126 N/A
1 set-up
TRUE
0
Uint8
9-19
Drive Unit System Number
1034 N/A
All set-ups
TRUE
0
Uint16
9-22
Telegram Selection
[100] None
1 set-up
TRUE
–
Uint8
9-23
Parameters for Signals
0
All set-ups
TRUE
–
Uint16
9-27
Parameter Edit
[1] Enabled
2 set-ups
FALSE
–
Uint16
9-28
Process Control
[1] Enable cyclic
master
2 set-ups
FALSE
–
Uint8
9-44
Fault Message Counter
0 N/A
All set-ups
TRUE
0
Uint16
9-45
Fault Code
0 N/A
All set-ups
TRUE
0
Uint16
9-47
Fault Number
0 N/A
All set-ups
TRUE
0
Uint16
Programming
VLT
®
Decentral Drive FCD 302