e3
0b
g4
54
.1
1
1
2
Illustration 151: STO Output Connector on the Top of DAM 510
e3
0b
h6
64
.1
0
3
4
Illustration 152: STO Input Connector on the Top of DAM 510
Table 145: Pin Assignment of STO Connectors on the Top of DAM 510
Connec-
tor name
Pins De-
scrip-
tion
Notes
Rating/parameter
STO DAM 1
STO–
Used for STO output
voltage to the input of
the other system
modules.
Nominal voltage: 24 V DC ±10%
Nominal current: Depends on the number of servo drives in the applica-
tion.
Maximum current: 1 A
Conductor cross-section range: 0.2–1.5 mm
2
(AWG 24–AWG 16)
2
STO+
3
STO–
Used for STO input
voltage.
4
STO+
N O T I C E
Only PELV potential can be connected to the STO inputs.
11.9.9.2.2 STO Connector on the Bottom of DAM 510
There is 1 output STO connector on the bottom of the Decentral Access Module (DAM 510). The output is for the hybrid cable.
AQ262449648484en-000101 / 175R1135
210 | Danfoss A/S © 2020.08
Specifications
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide