Illustration 99: Logical View of Direct Ethernet-based Fieldbus Communication
A
Ethernet-based fieldbus communication
B
VLT
®
Servo Toolbox host system
W A R N I N G
The logical view only shows the connectivity from a high-level software perspective and does not reflect the actual physical
topology of the network.
6.17.4.4.2 Network Settings for Direct Communication with Ethernet POWERLINK®
Disable all network protocols except TCP/IPv4 on the network interface used for direct Ethernet POWERLINK
®
communication. This
prevents other PC software or the operating system using this network interface for other tasks, such as file and printer sharing and
network discovery. Disabling these protocols reduces the number of non-relevant packets sent over the network interface and thus
reduces the overall network load.
6.17.4.4.3 Disabling Unused Protocols on the Network Interface on the PC
Procedure
Open the
Network and Sharing Center
.
On the left, click on
Change adapter settings
.
Right-click on the network interface used for fieldbus communication and select
Properties
.
Uncheck all checkboxes except the one for
Internet Protocol Version 4 (TCP/IPv4)
.
Disable the
IPv4 Checksum offload
on the network interfaces as described in
6.17.4.3.3 Enabling Indirect Communication
AQ262449648484en-000101 / 175R1135
136 | Danfoss A/S © 2020.08
Commissioning
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide