13-51 SL Controller Event
Array [20]
Option:
Function:
[80]
Digital input x46/3
[81]
Digital input x46/5
[82]
Digital input x46/7
[83]
Digital input x46/9
[84]
Digital input x46/11
[85]
Digital input x46/13
[90]
ATEX ETR cur. warning Selectable if
1-90 Motor Thermal
Protection
is set to
[20] ATEX ETR
or
[21] Advanced ETR
. If the alarm
164 ATEX ETR cur.lim.alarm is
active, the output will be 1.
[91]
ATEX ETR cur. alarm
Selectable if
1-90 Motor Thermal
Protection
is set to
[20] ATEX ETR
or
[21] Advanced ETR
]. If the alarm
166 ATEX ETR freq.lim.alarm is
active, the output will be 1.
[92]
ATEX ETR freq. warning Selectable if
1-90 Motor Thermal
Protection
is set to
[20] ATEX ETR
or
[21] Advanced ETR
. If the alarm
163 ATEX ETR cur.lim.warning is
active, the output will be 1.
[93]
ATEX ETR freq. alarm
Selectable if
1-90 Motor Thermal
Protection
is set to
[20] ATEX ETR
or
[21] Advanced ETR
. If the
warning 165 ATEX ETR
freq.lim.warning is active, the
output will be 1.
[94]
RS Flipflop 0
[95]
RS Flipflop 1
[96]
RS Flipflop 2
[97]
RS Flipflop 3
[98]
RS Flipflop 4
[99]
RS Flipflop 5
[100] RS Flipflop 6
[101] RS Flipflop 7
13-52 SL Controller Action
Array [20]
Option:
Function:
[0]
*
DISABLED
Select the action corresponding to the
SLC event. Actions are executed when
the corresponding event (defined in
) is evaluated as
true. The following actions are available
for selection:
[0] *DISABLED
[1]
No action
[2]
Select set-up 1
Changes the active set-up (
) to ‘1’.
13-52 SL Controller Action
Array [20]
Option:
Function:
If the set-up is changed, it will merge
with other set-up commands coming
from either the digital inputs or via a
fieldbus.
[3]
Select set-up 2
Changes the active set-up
) to ‘2’.
If the set-up is changed, it will merge
with other set-up commands coming
from either the digital inputs or via a
fieldbus.
[4]
Select set-up 3
Changes the active set-up (
) to ‘3’.
If the set-up is changed, it will merge
with other set-up commands coming
from either the digital inputs or via a
fieldbus.
[5]
Select set-up 4
Changes the active set-up (
) to ‘4’.
If the set-up is changed, it will merge
with other set-up commands coming
from either the digital inputs or via a
fieldbus.
[10] Select preset ref
0
Selects preset reference 0.
If the active preset reference is changed,
it will merge with other preset reference
commands coming from either the digital
inputs or via a fieldbus.
[11] Select preset ref
1
Selects preset reference 1.
If the active preset reference is changed,
it will merge with other preset reference
commands coming from either the digital
inputs or via a fieldbus.
[12] Select preset ref
2
Selects preset reference 2.
If the active preset reference is changed,
it will merge with other preset reference
commands coming from either the digital
inputs or via a fieldbus.
[13] Select preset ref
3
Selects preset reference 3.
If the active preset reference is changed,
it will merge with other preset reference
commands coming from either the digital
inputs or via a fieldbus.
[14] Select preset ref
4
Selects preset reference 4.
If the active preset reference is changed,
it will merge with other preset reference
commands coming from either the digital
inputs or via a fieldbus.
[15] Select preset ref
5
Selects preset reference 5.
If the active preset reference is changed,
it will merge with other preset reference
Parameter Descriptions
Operating Instructions VLT
®
CDS302 and CDS303
MG34M302 - VLT
®
is a registered Danfoss trademark/Commercial Compressor
95
6
6