Parameter
No.
Function
Range/number of settings/value
Factory setting
Data
type
Conv.
index
600
Operating data: Operating hours
0-130,000.0 hours
5
0
601
Operating data: Hours run
0-130,000.0 hours
7
73
603
Operating data: Number of power-up's
0-9999
7
73
604
Operating data: Number of overtemp.
0-9999
6
0
605
Operating data: Number of overvoltages 0-9999
6
0
615
Fault log, read-out: Error code
Index XX-XXX
6
0
616
Fault log, read-out: Time
Index XX-XXX
5
0
617
Fault log, read-out: Value
Index XX-XXX
7
-1
619
Reset of hours-run counter
No reset/reset
No reset
3
0
620
Operation mode
3
Normal function
5
0
621
Nameplate: FC motor type
Depends on unit
5
0
624
Nameplate: Software version no.
Depends on unit
9
0
625
LCP version
Depends on unit
9
0
626
Nameplate: Database identification no.
Depends on unit
9
0
628
Nameplate: Application option type
9
-2
630
Nameplate: Communication option type
9
0
632
BMC software identification
9
0
633
Motor database identification
9
0
634
Unit identification for communication
9
0
635
Software part No.
9
0
678
Configure Control Card
Depends on unit
5
0
Table 4.18 Functions to Programme, to Control and to Monitor via Bus (PROFIBUS) or by PC.
Conversion index:
This number refers to a conversion figure to be used when
writing or reading via serial communication with a
frequency converter.
See
in
Data type
:
Data type shows the type and length of the telegram.
Data type
Description
3
Integer 16
4
Integer 32
5
Unsigned 8
6
Unsigned 16
7
Unsigned 32
9
Text string
Table 4.19
All about FCM 300
VLT
®
DriveMotor FCM Series
94
MG03BA02 - VLT
®
is a registered Danfoss trademark
4
4
Summary of Contents for VLT Brook Crompton Motor FCM 300
Page 2: ......
Page 37: ...Programming VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 35 3 3...
Page 101: ...Index VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 99...
Page 102: ...www danfoss com drives MG03BA02 175R0087 MG03BA02 Rev 2011 12 22...