Description of choice:
Indicates the number of hours in which the FC motor has
been in operation since reset in parameter 619.
The value is updated in the FC motor every hour and
saved when the unit is turned off.
603
Operating data: Number of power-up’s
Value:
Unit: number
0-9999
Function:
This parameter can be read out via the display or the serial
communication port.
Description of choice:
States the number of power-ups of the supply voltage to
the FC motor.
604
Operating data: Number of overtemperatures
Value:
Unit: number
0-9999
Function:
This parameter can be read out via the display or the serial
communication port.
Description of choice:
States the number of temperature faults there has been on
the FC motor.
605
Operating data: Number of overvoltages
Value:
Unit: number
0-9999
Function:
This parameter can be read out via the display or the serial
communication port.
Description of choice:
States the number of overvoltages there has been on the
FC motor.
NOTICE
Parameters 615-617
Fault log
cannot be
read out via the integral control unit.
615
Fault log: Error code
Value:
[Index 1-10] Error code: 0-99
Function:
In this parameter it is possible to see the reason for a trip
(cut-out of the frequency converter) occurring. 10 [1-10]
log values are defined.
The lowest log number [1] contains the latest/most
recently saved data value. The highest log number [10]
contains the oldest data value saved. If a trip occurs, it is
possible to see the cause, time and a possible value of the
output current or output voltage.
Description of choice:
Given as a fault code, in which the number refers to a
table. See
4.2.1 List of Warnings and Alarms
616
Fault log: Time
Value:
Unit: Hours
[Indication range XX - XXX]
Function:
Array type parameter. This parameter makes it possible to
see the total number of operating hours before the trip
occurred. 10 (1-10) log values are stored.
The lowest log number (1) contains the latest/most
recently saved data value, while the highest log number
(10) contains the oldest data value.
Description of choice:
Read out as an option.
Indication range: XX - XXX.
The fault log is reset after initialization (para. 620).
617
Fault log: Value
Value:
[Index XX - XXX]
Function:
Array type parameter. This parameter makes it possible to
see at what current or voltage a given trip occurred.
Description of choice:
Read out as one value.
Indication range: 0.0 - 999.9.
The fault log is reset after initialisation (para. 620).
619
Reset of hours-run counter
Value:
No reset (DO NOT RESET)
[0]
Reset (RESET COUNTER)
[1]
Function:
Reset to zero of hours-run counter (parameter 601).
Description of choice:
If
[1] Reset
has been selected the hours-run counter of the
FC motor is reset.
620
Operating mode
Value:
Normal function (NORMAL OPERATION)
[0]
Control card test (CONTROL CARD TEST)
[2]
Initialisation (INITIALIZE)
[3]
Function:
In addition to its normal function, this parameter can be
used for two different tests.
Also, all parameters (except parameters 603-605) can be
initialized.
Description of choice:
[0] Normal function
is selected for normal operation with
the motor in the selected application.
Programming
VLT
®
DriveMotor FCM Series
MG03BA02 - VLT
®
is a registered Danfoss trademark
75
3
3
Summary of Contents for VLT Brook Crompton Motor FCM 300
Page 2: ......
Page 37: ...Programming VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 35 3 3...
Page 101: ...Index VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 99...
Page 102: ...www danfoss com drives MG03BA02 175R0087 MG03BA02 Rev 2011 12 22...