VLT
®
5000 FLUX
■
Digital and relay outputs
Digital outputs (Terminal 26 and 46, relay 01 and 04). Digital outputs are 0/24 V outputs Load : > 600 .
Common terminal (terminal 39) is the same for analog common and digital common. Relay 01 is placed on
the power board in the frequency converter. Relay 04 is placed on the control board.
Outputs
terminal no.
01(relay)
04 (relay)
46
26
parameter
323
326
341
355
Value:
No function
(NO OPERATION)
[0]
✭
[0]
✭
[0]
✭
[0]
✭
Control ready
(CONTROL READY)
[1]
[1]
[1]
[1]
Ready signal
(UNIT READY)
[2]
[2]
[2]
[2]
Ready - remote control
(UNIT READY/REM CTRL)
[3]
[3]
[3]
[3]
Enable, no warning
(ENABLE/NO WARNING)
[4]
[4]
[4]
[4]
Running
(VLT RUNNING)
[5]
[5]
[5]
[5]
Running, no warning
(RUNNING/NO WARNING)
[6]
[6]
[6]
[6]
Running within range, no warning
(RUN IN RANGE/NO WARN)
[7]
[7]
[7]
[7]
Running at reference value, no warning
(RUN ON REF/NO WARN)
[8]
[8]
[8]
[8]
Fault
(ALARM)
[9]
[9]
[9]
[9]
Fault or warning
(ALARM OR WARNING)
[10]
[10]
[10]
[10]
Torque limit
(TORQUE LIMIT)
[11]
[11]
[11]
[11]
Out of current range
(OUT OF CURRENT RANGE)
[12]
[12]
[12]
[12]
Over I low
(ABOVE CURRENT,LOW)
[13]
[13]
[13]
[13]
Under I high
(BELOW CURRENT,HIGH)
[14]
[14]
[14]
[14]
Out of speed range
(OUT OF SPEED RANGE)
[15]
[15]
[15]
[15]
Over n low
(ABOVE SPEED LOW)
[16]
[16]
[16]
[16]
Under n high
(BELOW SPEED HIGH)
[17]
[17]
[17]
[17]
Thermal warning
(THERMAL WARNING)
[21]
[21]
[21]
[21]
Ready - no thermal warning
(READY & NOTHERM WARN)
[22]
[22]
[22]
[22]
Ready - remote control - no therm.
warn.
(REM RDY & NO THERMWAR)
[23]
[23]
[23]
[23]
Ready - mains voltage within range
(RDY NO OVER/UNDERVOL)
[24]
[24]
[24]
[24]
Reversing
(REVERSE)
[25]
[25]
[25]
[25]
Bus ok
(BUS OK)
[26]
[26]
[26]
[26]
Torque limit and stop
(TORQUE LIMIT AND STOP)
[27]
[27]
[27]
[27]
Brake, no brake warning
(BRAKE NO BRAKE WARNING)
[28]
[28]
[28]
[28]
Brake ready, no fault
(BRAKE RDY (NO FAULT))
[29]
[29]
[29]
[29]
Brake fault
(BRAKE FAULT (IGBT))
[30]
[30]
[30]
[30]
Relay 123
(RELAY 123)
[31]
[31]
[31]
[31]
Mechanical brake control
(MECH. BRAKE CONTROL)
[32]
[32]
[32]
1)
[32]
1)
Control word bit 11/12
(CTRL WORD BIT 11/12)
[33]
[33]
[33]
[33]
Ref
MIN
- Ref
MAX
⇒
0-50000 p
(REF MIN-MAX = 0-50000P)
[34]
[34]
0 - I
MAX
⇒
0-50000 p
(0-IMAX = 0-50000P)
[36]
[36]
0 - T
LIM
⇒
0-50000 p
(0-TLIM = 0-50000P)
[37]
[37]
0 - T
NOM
⇒
0-50000 p
(0-TNOM = 0-50000P)
[38]
[38]
0 - P
NOM
⇒
0-50000 p
(0-PNOM = 0-50000P)
[39]
[39]
0 - MAX SPEED
⇒
0-50000 p
(0-MAX SPD. = 0-50000P)
[40]
[40]
+/-160% TORQ
⇒
0-50000 p
(+/-160% TORQ= 0-50000P)
[41]
[41]
1) When mechanical brake control is selected, output 46 and 26 are inverted.
Function:
Description of choice:
Control ready
, the frequency converter is ready for
use; the control board receives supply voltage.
Ready signal
, the frequency converter control board
is receiving a supply signal and the frequency
converter is ready for operation.
Ready, remote control
, the frequency converter control
board is receiving a supply signal and parameter
002 has been set to
remote control.
Enable, no warning
, the frequency converter is
ready for use; no start or stop command has been
given (start/disable). No warning.
Running
, a start command has been given.
Running, no warning
, the output speed is higher
than the speed set in parameter 123. A start
command has been given. No warning.
Runs in range, no warning
, runs within the programmed
current/speed ranges set in parameters 223-226.
✭
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.55.A6.02 - VLT is a registered Danfoss trademark
96