VLT
®
5000 FLUX
Control Panel
(LCP)
■
Control panel (LCP)
The front of the frequency converter features a
control panel - LCP(Local Control Panel), which
makes up a complete interface for operation and
monitoring of the frequency converter.
The control panel is detachable and can - as an
alternative - be installed up to 3 metres away from
the frequency converter, e.g. on a front panel,
by means of a mounting kit option.
The functions of the control panel can be
divided into three groups:
•
display
•
keys for changing program parameters
•
keys for local operation
All data are shown in a 4-line alpha-numeric
display, which in normal operation is able to show
4 measurements and 3 operating conditions
continuously. During programming, all the information
required for quick, effective parameter Setup of the
frequency converter will be displayed. Additional
three LEDs for indicating voltage (power or 24
V external), warning and alarm.
All program parameters can be changed immediately
from the control panel, unless this function has
been blocked via parameter 018.
■
Display
175ZA734.10
SETUP
1
1. Line
2.
Line
3. Line
4. Line
1st line
shows up to 3 measurements continuously
in normal operating status or a text which
explains the 2 nd line.
2nd line
shows a measurement with related
unit continuously, regardless of status (except
in the case of alarm/warning).
3rd line
is normally blank and is used in the menu
mode to show the selected parameter number or
parameter group number and name.
4th line
is used in operating status for showing a status
message text or in data change mode for showing
the mode or value of the selected parameter.
An arrow indicates the direction of rotation of the
motor. Furthermore, the Setup which has been
selected as the Active Setup in parameter 004 is
shown. When programming another Setup than
the Active Setup, the number of the Setup which
is being programmed will appear to the right. This
second Setup number will flash.
■
LEDs
If certain threshold values are exceeded, the red alarm
and/or yellow warning LED light(s) up together with a
status and alarm text on the control panel.
The ON LED is activated when the frequency converter
is connected to mains, or 24 V external supply; at the
same time the rear lighting of the display will be on.
■
Control keys
The control keys are divided into functions. This means
that the keys between display and indicator lamps
are used for parameter Setup, including choice of
display indication during normal operation.
Parameter setup keys:
The frequency converter can be used for
practically all assignments and offers a choice
between two programming modes - a Menu
mode and a Quick menu mode.
Menu mode provides access to all parameters.
Quick menu mode takes the user through a few
parameters which make it possible to easy start
operating the frequency converter.
A change of a parameter will take effect and be visible
both in the Menu mode and in the Quick menu mode.