VLT
®
5000 FLUX
■
Introduction
Parameter group 3xx selects the analog and digital inputs and outputs to the desired function. Also scaling of
the inputs and outputs is performed in this group. Inputs: Max frequency on inputs terminal 16, 17, 18, 19,
27, 32, and 33 is 5 kHz. (24Vpp). Max frequency on inputs terminal 29 is 65 kHz (24Vpp).
Max frequency for the encoder inputs terminal 73 - 78 is 250 kHz (5Vpp). Outputs: Analog outputs terminal
42 and 45 are scaleable current outputs. Max frequency on digital outputs terminal 26 and 46 is 50kHz.
PNU
Parameter
Factory setting
Range
Changes
4-Setup
Conver-
sion
Data
#
description
during operation
index
type
300
Terminal 16, input
Reset
Yes
Yes
0
5
301
Terminal 17, input
Freeze reference
Yes
Yes
0
5
302
Terminal 18 Start, input
Start
Yes
Yes
0
5
303
Terminal 19, input
Reversing
Yes
Yes
0
5
304
Terminal 27, input
Coasting stop, inverse
Yes
Yes
0
5
305
Terminal 29, input
Jog
Yes
Yes
0
5
306
Terminal 32, input
Choice of setup, msb/speed up
Yes
Yes
0
5
307
Terminal 33, input
Choice of setup, lsb/speed down
Yes
Yes
0
5
308
Terminal 53, analog input voltage
Reference
Yes
Yes
0
5
309
Terminal 53, min. scaling
0.0 V
0.0 - 10.0 V
Yes
Yes
-1
5
310
Terminal 53, max. scaling
10.0 V
0.0 - 10.0 V
Yes
Yes
-1
5
311
Terminal 54, analog input voltage
No operation
Yes
Yes
0
5
312
Terminal 54, min. scaling
0.0 V
0.0 - 10.0 V
Yes
Yes
-1
5
313
Terminal 54, max. scaling
10.0 V
0.0 - 10.0 V
Yes
Yes
-1
5
314
Terminal 60, analog input current
Reference
Yes
Yes
0
5
315
Terminal 60, min. scaling
0.0 mA
0.0 - 20.0 mA
Yes
Yes
-4
5
316
Terminal 60, max. scaling
20.0 mA
0.0 - 20.0 mA
Yes
Yes
-4
5
317
Time out
10 sec.
0 - 99 sec.
Yes
Yes
0
5
318
Function after time out
Off
Yes
Yes
0
5
319
Terminal 42, output
0 - n
MAX
⇒
0-20 mA
Yes
Yes
0
5
321
Terminal 45, output
0 - n
MAX
⇒
0-20 mA
Yes
Yes
0
5
323
Relay 01, output
No operation
Yes
Yes
0
5
324
Relay 01, ON delay
0.00 sec.
0.00 - 600.00 sec.
Yes
Yes
-2
6
325
Relay 01, OFF delay
0.00 sec.
0.00 - 600.00 sec.
Yes
Yes
-2
6
326
Relay 04, output
No operation
Yes
Yes
0
5
327
Pulse reference, max. frequency
100 - 65000 Hz
5000 Hz
Yes
Yes
0
6
329
Encoder feedback pulse/rev.
1024 pulses/rev.
500 - 10.000 pulses/rev.
Yes
Yes
0
6
341
Terminal 46, digital output
No operation
Yes
Yes
0
5
342
Terminal 46, output, pulse scaling
5000 Hz
1 - 50000 Hz
Yes
Yes
0
6
350
Encoder monitoring
OFF
No
No
0
5
351
Encoder direction
Normal
No
Yes
0
5
355
Terminal 26, digital output
No operation
Yes
Yes
0
5
356
Terminal 26, output, pulse scaling
5000 Hz
1 - 50000 Hz
Yes
Yes
0
6
357
Terminal 42, Output minimum scaling
0 %
000 - 100%
Yes
Yes
0
6
358
Terminal 42, Output maximum scaling
100%
000 - 500%
Yes
Yes
0
6
359
Terminal 45, Output minimum scaling
0 %
000 - 100%
Yes
Yes
0
6
360
Terminal 45, Output maximum scaling
100%
000 - 500%
Yes
Yes
0
6
361
Max Tracking Error
OFF
000 - 999 rpm
Yes
Yes
0
6
362
KTY Sensor Type
KTY1
KTY 1-3
No
Yes
0
5
See also
Operation and Display
for further
information regarding Changes during operation,
4-Setup and Conversion index.
✭
= factory setting. () = display text [] = value for use in communication via serial communication port