background image

Instruction  

SONOMETER™ 1100

DEN-SMT/PL 

 

 

 

 

 

VI.SH.K1.02 

 

 

               Danfoss District Enrgy

8

9.0 Display

To show the data generated by the calculator in the display, various win-
dows are provided as loop functions that can be called up in succession to 
display the system information associated with each window (e.g. energy 
amounts, water volume, running days, water amounts, current tempera-
tures). The energy meter has 6 different display loops.

  

The various display windows comprise up to several displays that 
change at intervals of 2 – 4 s. The loops in the display are numbered 1, 
2, ... and 6 to help the user find his way around quickly. The main loop 
is programmed with the current data as default setting, e.g. for energy, 
volume and flow rate.

Informative Displays (Standard)

Loop

Sequence

Window 1

Window 2

Window 3

“1”

Main loop

1.1

Accumulated energy

1.2

Volume

1.3

Accumulated energy (cooling)

(Sequence will be shown only 

in a heat meter with cooling tariff)

1.4

Flow

1.5

Power

1.6

Forward ⁄ - return temperature

1.7

Temperature difference

1.8

Operating days

Error hours

1.9

Error status

1.10

Display test

Loop

Sequence

Window 1

Window 2

Window 3

“2”

Accounting

date loop

2.1

Accounting date 1

Accounting date 1 energy

‚Accd 1A’

2.2

‚Accd 1’

Future accounting date 1

2.3

Accounting date 1 previous year

Accounting date 1 

previous year energy

‚Accd 1L’

2.4

Accounting date 2

Accounting date 2 energy

‚Accd 2A’

2.5

‚Accd 2’

Future accounting date 2

2.6

Accounting date 2 previous year

Accounting date 2 

previous year energy

‚Accd 2L’

...

2.14

Accounting date 2 previous year

Pulse input 2

Pulse input volume 2

Loop

Sequence

Window 1

Window 2

Window 3

“3“

Info loop

3.1

Current date

Current time

3.2

,SEC_Adr'

Secondary address

3.3

,Pri_Adr 1'

Primary address 1

3.4

,Pri_Adr 2'

Primary address 2

3.5

Installation position

3.6

,Port 1’

No. of the mounted module at port 1

3.7

,Port 2’

No. of the mounted module at port 2

3.8

Status integrated radio

(Sequence will be shown only in 

meters with integrated radio)

3.9

 software version

Checksum

Loop

Sequence

Window 1

Window 2

Window 3

“4”

Pulse input

loop

4.1

,In1'

Accumulated value  pulse input 1

,PPI' pulse value 1

4.2

,In2'

Accumulated value  pulse input 2

,PPI' pulse value 2

Loop

Sequence

Window 1

Window 2

Window 3

Window 4

Window 5

Window 6

“5”

Tariff loop

Only in a heat meter with cooling tariff.

Loop

Sequence

Window 1

Window 2

Window 3

Window 4

Window 5

Window 6

“6”

Monthly value

loop

6.1

,LOG’

date last month

energy

volume

max. flow rate

max. power

6.2

,LOG’

date month - 1

energy

volume

max. flow rate

max. power

6.3

,LOG’

date month - 2

energy

volume

max. flow rate

max. power

...

...

6.24

,LOG’

date month - 23

energy

volume

max. flow rate

max. power

Summary of Contents for SONOMETER 1100

Page 1: ...Sheet FW510 If water additives are used e g corrosion protection the user must make sure that the corrosion resistance is adequate The specified medium temperature is 5 90 C 105 C 130 C 150 C The tem...

Page 2: ...low sensor in a tilted 45 position The minimum system pressure must be 1 bar to avoid cavitation Make sure the energy meter is installed sufficiently far away from possible sources of electromagnetic...

Page 3: ...be inserted as far as the bottom of the pocket and then secured The pockets are best installed inT pieces with a 45 or 90 angle The tip of the pocket must point in the opposite direction to the direct...

Page 4: ...on pressing button and the date and time are still updated but none of the measuring functions work incl the flow rate measurement Communication still functions over the optional M Bus RS485 and RS23...

Page 5: ...e formed ribbon cable at both ends 3 Close the lid and check the meter for correct operation by pressing the push button loop 3 Renew the seal of the housing lid if the meter functions correctly The r...

Page 6: ...tandard and is encrypted Reading modes Walk By Drive By Fixed Network For problematic radio installations shield the external radio module set can also be used 8 2 M Bus communication module The M Bus...

Page 7: ...nd can be used as the supply for a flow sensor The pulse output has the same characteristics as pulse output 1 speci fied under 8 6 It is not however electrically isolated 8 8 Analogue output function...

Page 8: ...Future accounting date 1 2 3 Accounting date 1 previous year Accounting date 1 previous year energy Accd 1L 2 4 Accounting date 2 Accounting date 2 energy Accd 2A 2 5 Accd 2 Future accounting date 2...

Page 9: ...prox 4 minutes The error display disappears automatically as soon as the cause of the error has been cleared All errors present longer than 6 minutes are saved in the error log Error code Description...

Page 10: ...Instruction SONOMETER 1100 VI SH K1 02 Produced by Danfoss A S 12 2014...

Reviews: