7. Using a 5 mm internal hex wrench, torque the cap screws (D250) to 13.5 N•m [10 lbf•ft].
HC ECD Control
P108776
D250 (6X)
5 mm
D150
D200
D300 (2X)
D084
Torque sequence
2
3
4
5
6
1
Service Manual
Series 40 M46 Variable Pumps
Minor repair
©
Danfoss | September 2017
11026743 | AX00000027en-US0202 | 43