background image

Danfoss Heating

9

GB

Occasionally you may need to remove a thermostat or other Z-Wave 

device from the RZ1 receiver. To do this, follow the procedure below:

1.  Press 

PROG

 to set the RZ1 into 

PROGRAMME

 mode.

2.   Press  the  button  for  the  associated  channel  to  be  un-bound/

disconnected (

RED channel LED will flash

).

3.   Press the ‘exclude initiator’ button on the device to be removed 

(On some devices you may need to press and hold the include 

initiator button for up to 10 seconds).

4.   When  the  device  has  been  removed,  the 

RED

 

LED

  for  that 

channel will illuminate continuously.

5.  Press 

PROG

 to return to normal operating mode.

4.1  Disconnecting devices from the RZ1

4.2  Include devices to the network, 

 

not using the RZ1 relay output

If you wish to include a device to the network but not use the relay 

function of the RZ1, follow this procedure:

1.  Press the 

PROG

 button the

 PROG LED

 should turn 

RED

.

2.  Press the 

PROG

 button for at least 3 seconds or until the 

PROG 

LED

 goes out.

3.  Press and release within 3 seconds the 

PROG

 button, the 

PROG 

LED

  should  flash 

RED

  slowly  indicating  that  an  inclusion  has 

started.

4.  Begin the inclusion process on your remote device.

5.  If the process is successful the 

PROG LED

 will show solid 

RED

Press 

PROG

 to return to normal operating mode.

6.  If unsuccessful the 

PROG LED

 will flash 

ORANGE

 quickly. Press 

the 

PROG

 button to return to step 1 and try again.

7.  Once the inclusion is successfully completed, press the 

PROG

 

button to return to normal operating mode.

Summary of Contents for RZ1

Page 1: ...Z Wave Electronic Radio Frequency Receivers 1 Channel RZ1 and RZ1 HP Installation Guide Danfoss Heating MAKING MODERN LIVING POSSIBLE...

Page 2: ...ng on 0845 121 7400 Danfoss can accept no responsibility for possible errors in catalogues brochures and other printed material All trademarks in this material are property of the respective companies...

Page 3: ...the RZ1 as a secondary controller to a network 10 4 5 Excluding the RZ1 as a secondary controller to a network 11 5 0 Implementing a network controller shift 12 5 1 Initiating a primary controller sh...

Page 4: ...20 1 Maximum Ambient Temperature 45 C Switch Type 1 x SPDT type 1B Switch Rating 230 Vac 3 1 A Total current 230 Vac 12 6 A Total current IP Rating IP 40 Control Pollution Situation Degree 2 Max Range...

Page 5: ...danfoss Heating 5 GB 2 0 Mounting Instructions...

Page 6: ...RZ1 and RZ1 HP 6 GB 1 2 3 4 ELECTRONICS N L COM ZONE 1 ON ZONE 1 OFF Note For mains voltage applications link terminals L and 2 2 1 Wiring RZ1...

Page 7: ...Unbind button press request Green Normal Run Mode Green slow flash Factory Reset State Red Programme Mode Red slow flash Binding association in progress Orange Primary controller shift mode enabled Or...

Page 8: ...ROG LED will light up RED 2 Channels with no devices bound will show RED LED as well 3 Press the button for the channel you wish to bind the LED will flash RED slowly 4 Press the include initiator but...

Page 9: ...from the RZ1 4 2 Include devices to the network not using the RZ1 relay output If you wish to include a device to the network but not use the relay function of the RZ1 follow this procedure 1 Press th...

Page 10: ...ion is successfully completed press the PROG button to return to normal operating mode PROG LED GREEN 4 3 Exclude devices not using the RZ1 relay output from the network If you already have a primary...

Page 11: ...ode by pressing the PROG button Programme LED will turn RED 2 Activate the exclude unbind initiator on the primary controller in the network 3 Press and hold the programme and channel buttons until th...

Page 12: ...r 5 If the process is successful the PROG LED will show solid RED failure will be indicated by the PROG LED flashing ORANGE 6 To return to normal RUN mode press the PROG button the LED will show GREEN...

Page 13: ...4 4 NOTE It is the responsibility of the existing network controller to initiate a controller shift which the RZ1 will support 6 0 Using the Protection Capabilities This product supports the Z Wave p...

Page 14: ...l network information from the unit it is advisable to perform a factory reset 1 Press PROG to place the receiver in PROGRAMME mode Red LED illuminated continuously 2 Press and hold CH1 button for at...

Page 15: ...ice is waiting for instructions to switch on or off its output s Reset State In the Reset State the RZ1 is reset back to factory defaults and is ready to either be added into an existing network as a...

Page 16: ...Part No RZ1v04_Installation Danfoss Randall Ltd Ampthill Road Bedford MK42 9ER Tel 0845 1217 400 Fax 0845 1217 515 Email danfossrandall danfoss com Website www danfoss randall co uk...

Reviews: