Binding

The  act  of  linking  a  remote  wireless  unit  (i.e. 

thermostat  or  time  controller)  to  the  RZ1 

receiver channel

Channel

The output of the RZ1 unit. RZ1 has one channel.  

Each of these channels can be used to control a 

device that requires switching on.

Include/Exclude

Initiator Button

On every Z-Wave product there will be a button 

or process to tell the device to send out a request 

to join or leave an existing or new network.  

LED

Light  Emitting  Diode.  The  RZ1  has  tri-colour 

LEDs to indicate the different states the control 

can be in.

Programme State

The  RZ1  is  ready  to  include  or  exclude  other 

Z-Wave compatible devices from the network.

Ready State

When  the  RZ1  is  in  ready  state  the  GREEN 

PROG  LED  is  lit  and  the  device  is  waiting  for 

instructions to switch on or off its output(s).

Reset State

In the Reset State the RZ1 is reset back to factory 

defaults  and  is  ready  to  either  be  added  into 

an  existing  network  as  a  secondary  controller 

or to be used to create a network as a primary 

controller.

Z-Wave

A  wireless  communication  protocol  designed 

for  low-power  and  low-bandwidth  appliances, 

such as home automation and sensor networks

SUC

(Static Update 

Controller

A  secondary  controller  that  acts  as  a  back  up 

store of the network routings. The SUC can be 

used to create a new primary network controller 

if commanded to, should the primary controller 

malfunction.  Only  the  primary  controller  can 

include new devices with a SUC in the network

SIS 

(SUC ID Server)

A  SUC  controller  which  has  been  promoted 

by  the  network  to  become  the  ID  server.  Any 

device in the network can include new nodes to 

the network, not just the primary device.

9.0  Glossary

Summary of Contents for RZ1

Page 1: ...Z Wave Electronic Radio Frequency Receivers 1 Channel RZ1 and RZ1 HP Installation Guide Danfoss Heating MAKING MODERN LIVING POSSIBLE...

Page 2: ...ng on 0845 121 7400 Danfoss can accept no responsibility for possible errors in catalogues brochures and other printed material All trademarks in this material are property of the respective companies...

Page 3: ...the RZ1 as a secondary controller to a network 10 4 5 Excluding the RZ1 as a secondary controller to a network 11 5 0 Implementing a network controller shift 12 5 1 Initiating a primary controller sh...

Page 4: ...20 1 Maximum Ambient Temperature 45 C Switch Type 1 x SPDT type 1B Switch Rating 230 Vac 3 1 A Total current 230 Vac 12 6 A Total current IP Rating IP 40 Control Pollution Situation Degree 2 Max Range...

Page 5: ...danfoss Heating 5 GB 2 0 Mounting Instructions...

Page 6: ...RZ1 and RZ1 HP 6 GB 1 2 3 4 ELECTRONICS N L COM ZONE 1 ON ZONE 1 OFF Note For mains voltage applications link terminals L and 2 2 1 Wiring RZ1...

Page 7: ...Unbind button press request Green Normal Run Mode Green slow flash Factory Reset State Red Programme Mode Red slow flash Binding association in progress Orange Primary controller shift mode enabled Or...

Page 8: ...ROG LED will light up RED 2 Channels with no devices bound will show RED LED as well 3 Press the button for the channel you wish to bind the LED will flash RED slowly 4 Press the include initiator but...

Page 9: ...from the RZ1 4 2 Include devices to the network not using the RZ1 relay output If you wish to include a device to the network but not use the relay function of the RZ1 follow this procedure 1 Press th...

Page 10: ...ion is successfully completed press the PROG button to return to normal operating mode PROG LED GREEN 4 3 Exclude devices not using the RZ1 relay output from the network If you already have a primary...

Page 11: ...ode by pressing the PROG button Programme LED will turn RED 2 Activate the exclude unbind initiator on the primary controller in the network 3 Press and hold the programme and channel buttons until th...

Page 12: ...r 5 If the process is successful the PROG LED will show solid RED failure will be indicated by the PROG LED flashing ORANGE 6 To return to normal RUN mode press the PROG button the LED will show GREEN...

Page 13: ...4 4 NOTE It is the responsibility of the existing network controller to initiate a controller shift which the RZ1 will support 6 0 Using the Protection Capabilities This product supports the Z Wave p...

Page 14: ...l network information from the unit it is advisable to perform a factory reset 1 Press PROG to place the receiver in PROGRAMME mode Red LED illuminated continuously 2 Press and hold CH1 button for at...

Page 15: ...ice is waiting for instructions to switch on or off its output s Reset State In the Reset State the RZ1 is reset back to factory defaults and is ready to either be added into an existing network as a...

Page 16: ...Part No RZ1v04_Installation Danfoss Randall Ltd Ampthill Road Bedford MK42 9ER Tel 0845 1217 400 Fax 0845 1217 515 Email danfossrandall danfoss com Website www danfoss randall co uk...

Reviews: