background image

Danfoss Heating

7

GB

3.0  Understanding your RZ1

The RZ1 receiver unit uses a combination of coloured LEDs to indicate 

the current operating mode/output status.  For the purpose of this 

document the indicator lights will be split into two distinct groups; 

CHANNEL LEDs and PROGRAMME LED.  More information is  listed 

below together with explanations of each of the LED colour states.

Programme 

LED

Channel LED

Programme LED

Off

Awaiting Bind/Unbind button press request

Green

Normal Run Mode

Green (slow flash) Factory Reset State
Red

Programme Mode

Red (slow flash)

Binding/association in progress

Orange

Primary controller shift mode enabled

Orange (fast flash) Failed to bind

Channel LED(s) - Programme Mode

Off

Channel Bound/Associated

Red

Channel not Bound/Associated

Red (slow flash)

Channel in process of being 

bound/associated

Channel LED(s) - Run Mode

Off

Output OFF

Green

Output ON

Red

Channel not Bound

Red (fast flash)

Channel Bound but no communication

Red (slow flash)

Channel manually overridden to an OFF state

Green/Orange 

(slow flash)

Channel manually overridden to an ON state

Summary of Contents for RZ1

Page 1: ...Z Wave Electronic Radio Frequency Receivers 1 Channel RZ1 and RZ1 HP Installation Guide Danfoss Heating MAKING MODERN LIVING POSSIBLE...

Page 2: ...ng on 0845 121 7400 Danfoss can accept no responsibility for possible errors in catalogues brochures and other printed material All trademarks in this material are property of the respective companies...

Page 3: ...the RZ1 as a secondary controller to a network 10 4 5 Excluding the RZ1 as a secondary controller to a network 11 5 0 Implementing a network controller shift 12 5 1 Initiating a primary controller sh...

Page 4: ...20 1 Maximum Ambient Temperature 45 C Switch Type 1 x SPDT type 1B Switch Rating 230 Vac 3 1 A Total current 230 Vac 12 6 A Total current IP Rating IP 40 Control Pollution Situation Degree 2 Max Range...

Page 5: ...danfoss Heating 5 GB 2 0 Mounting Instructions...

Page 6: ...RZ1 and RZ1 HP 6 GB 1 2 3 4 ELECTRONICS N L COM ZONE 1 ON ZONE 1 OFF Note For mains voltage applications link terminals L and 2 2 1 Wiring RZ1...

Page 7: ...Unbind button press request Green Normal Run Mode Green slow flash Factory Reset State Red Programme Mode Red slow flash Binding association in progress Orange Primary controller shift mode enabled Or...

Page 8: ...ROG LED will light up RED 2 Channels with no devices bound will show RED LED as well 3 Press the button for the channel you wish to bind the LED will flash RED slowly 4 Press the include initiator but...

Page 9: ...from the RZ1 4 2 Include devices to the network not using the RZ1 relay output If you wish to include a device to the network but not use the relay function of the RZ1 follow this procedure 1 Press th...

Page 10: ...ion is successfully completed press the PROG button to return to normal operating mode PROG LED GREEN 4 3 Exclude devices not using the RZ1 relay output from the network If you already have a primary...

Page 11: ...ode by pressing the PROG button Programme LED will turn RED 2 Activate the exclude unbind initiator on the primary controller in the network 3 Press and hold the programme and channel buttons until th...

Page 12: ...r 5 If the process is successful the PROG LED will show solid RED failure will be indicated by the PROG LED flashing ORANGE 6 To return to normal RUN mode press the PROG button the LED will show GREEN...

Page 13: ...4 4 NOTE It is the responsibility of the existing network controller to initiate a controller shift which the RZ1 will support 6 0 Using the Protection Capabilities This product supports the Z Wave p...

Page 14: ...l network information from the unit it is advisable to perform a factory reset 1 Press PROG to place the receiver in PROGRAMME mode Red LED illuminated continuously 2 Press and hold CH1 button for at...

Page 15: ...ice is waiting for instructions to switch on or off its output s Reset State In the Reset State the RZ1 is reset back to factory defaults and is ready to either be added into an existing network as a...

Page 16: ...Part No RZ1v04_Installation Danfoss Randall Ltd Ampthill Road Bedford MK42 9ER Tel 0845 1217 400 Fax 0845 1217 515 Email danfossrandall danfoss com Website www danfoss randall co uk...