GetParameter
This message is used to retrieve a value of a given parameter. If an unknown parameter value is
requested, no response will be sent back. Timeout policy shall be applied.
CAN message
Priority
6
PGN
61184
XID
0x0FA0 (MSB first)
Occurrence
when required
Modes
operational, reduced, calibration and fault
Sent by
configuration tool, high priority external set-point controller
Sent to
PVED-CL
Data field
Bytes
Encoding
Value/Range
Description
1, 2
UNSIGNED16
0x0FA0 (MSB first)
extended message identifier (XID)
3, 4
UNSIGNED16
(see parameter list)
parameter index
GetParameterResponse
This message is sent upon the GetParameter request and contains both parameter index and parameter
value.
CAN message
Priority
6
PGN
61184
XID
0x0FA1 (MSB first)
Occurrence
upon request
Modes
operational, reduced, calibration and fault
Sent by
PVED-CL
Sent to
configuration tool or high priority external set-point controller
Data field
Bytes
Encoding
Value/Range
Description
1, 2
UNSIGNED16
0x0FA1 (MSB first)
extended message identifier (XID)
3, 4
UNSIGNED16
(see parameter list)
parameter index
5 – 8
UNSIGNED32
(depends on a
parameter)
parameter value
SetParameter
This message is used to set value of a given parameter. Please note that the values are not stored in non-
volatile memory unless CommitData command is sent.
Technical Information
PVED-CL Communication Protocol, version 1.38 Technical Information
Configuration
11079551 • Rev BA • July 2014