1.
-
-
-
-
6.3 Configuring Port Mirroring Settings
Enable/disable the port-mirroring function for network troubleshooting with a network analyzer tool.
In MyDrive Insight, go to
Setup and Service
→
Interface Configuration
→
Port Mirroring Settings
.
Table 18: Port Mirroring Settings
Function
Selections
Description
Source port
X1
X2
Frames are mirrored from this port.
Destination port
X1
X2
Frames are mirrored to this port.
Block RX from destination port Enable/disable Device does not receive any frames from Destination Port when en-
abled.
Enable port mirroring
Enable/disable Enable the Port Mirroring feature.
6.4 Identifying a Drive
For easy identification of a drive, the winking function makes the fieldbus indicator LEDs ST, X1, and X2 flash yellow. The function is
enabled in MyDrive
®
Insight under
Device Status
, by clicking the device name in live mode.
e3
0b
k7
63
.1
0
Illustration 12: Enabling Winking in MyDrive
®
Insight
for more information on interpreting the LED signals.
6.5 Fieldbus Indicator LEDs
The fieldbus indicator LEDs are in the top right corner of the control panel.
AQ408626183394en-000101 / 136R0280 | 29
Danfoss A/S © 2023.06
Troubleshooting
iC7 Series PROFINET
Operating Guide