background image

Setting up the speed

NO SWITCH (MANUAL I/O, TILT, ETC.) IS ALLOWED 
TO BE CONNECTED IN SERIES WITH THE 
THERMOSTAT. IF ELECTRONIC THERMOSTATS 
ARE TO BE FIT, AVOID THOSE THAT INCORPORATE 
MANUAL I/O SWITCH AND/OR STARTING DELAY. 

• Sleep mode:

Compressor will run during four hours after 
start-up. The speed can be limited by a fixed 
programmed value and even more by the 
available battery voltage as described in standard 
mode. The speed can also be limited by external 
switching in a similar way as described in 
standard mode according to table 5:

If off sleep mode is selected, the appliance will 
run continuously at selected fixed speed Smin or 
Smax. 

• Sleep Energy Saving mode:

Compressor will run during four hours. During 
first hour compressor will run at selected speed. 
During next three hours speed will decrease up 
to 2,000 r.p.m. Programming Sleep Energy Saving 
is done in the same way as Sleep. 

• Slave mode:

Under this mode, variable speed is controlled by 
an Electronic Integral Manager of the appliance 
(EIM) permanently connected to the electronic 

driver FDC3 through the SPI, using its serial 
communication capability. The EIM reads the 
current temperature inside the appliance, 
compares it with the set point temperature, and 
decides if the compressor should operate or not, 
and if so, at which speed. The EIM communicates 
how the compressor should operate and, 
eventually, records and displays any abnormal 
circumstance that might occur. For details about 
the communication protocol, please contact 
Danfoss. 

IF ANY VARIABLE SPEED MODE IS TO BE 
PROGRAMMED, CHECK CAREFULLY FOR TUBES, 
CONDENSER AND EVAPORATOR RESONANCES. 
NATURAL FREQUENCIES SHOULD BE 75 Hz UP TO 
AVOID VIBRATIONS.

Table 5. External 

selection of the velocity  

0=Open connection; 

1=Shortened

Connection to COM

Speed of the

motors (rpm)

Sleep mode

IN1

IN2

0

0

Smin

off

1

0

Smin

on

0

1

Smax

off

1

1

Smax

on

12

FRCC.PC.041.A1.02

Summary of Contents for GLT80TDC

Page 1: ...Danfoss Light Commercial Refrigeration Compressors GLT80TDC Direct Current 24 42V Mobile Applications Application guidelines http cc danfoss com...

Page 2: ......

Page 3: ...Wiring and Connections 6 The serial port interface 8 Operating voltage 9 Battery protection system 10 Setting up the speed 12 Programming the electronic driver 13 Protections and alarms 14 Compressor...

Page 4: ...ppliance EIM and making the compressor work in slave mode FDC3 electronic driver includes Smart Speed as programming option which is a plug in system for automatically self adapting compressor speed t...

Page 5: ...been stopped during a certain period of time with an inclination higher than 15 it is strongly recommended to not start up the compressor immediately after coming back to the correct position We recom...

Page 6: ...FUSE MUST BE PLACED BETWEEN THE POLE OF THE BATTERY OR DC POWER SUPPLY AND THE POWER INPUT TERMINAL OF THE ELECTRONIC DRIVER 12V SYSTEMS 30A FUSE 24V SYSTEMS 30A FUSE 42V SYSTEMS 20A FUSE In some spe...

Page 7: ...iagram Fig 2 FDC3 wiring scheme Fig 3 Connection of FDC3 driver to the compressor The FDC3 electronic driver features a terminal board where all connections are made The terminal lay out is described...

Page 8: ...y alarm Set up either the compressor speed or the battery protection level through physical connections between IN1 IN2 and COM Connect the electronic driver as slave to an Electronic Integral Manager...

Page 9: ...is within 33 and 42 4V Special programming option The compressor can be powered by a variable DC source as for instance a photovoltaic panel in which the output voltage strongly depends on the intens...

Page 10: ...0 40 0 2 0 3 0 Special 9 0 40 0 1 0 3 0 Externally using COM IN1 and IN2 of SPI This option prevents from the possibility of setting up the speed externally using COM IN1 and IN2 of SPI as defined in...

Page 11: ...than the maximum nominal voltage 14V 28V and 42V for 12V 24V and 42V systems respectively A linear function of the battery voltage in the range between the cut in and the maximum nominal voltages This...

Page 12: ...Sleep Energy Saving is done in the same way as Sleep Slave mode Under this mode variable speed is controlled by an Electronic Integral Manager of the appliance EIM permanently connected to the electro...

Page 13: ...incompatible with external battery protection step 8 2 7 2 Smart Speed mode Select maximum fixed speed or external switcher connected to SPI and proceed as described in 7 1 1 or 7 1 2 respectively 7 3...

Page 14: ...om the power supply The intervention of the thermostat during the sequence of automatic restart attempts interrupts and resets the sequence The SPI can be configured in a way that a LED can be connect...

Page 15: ...rd ON OFF according with CECOMAF GT 4004 standard Vibrations according with ASTM 5728 Level I standard Application Application MBP HBP A C Refrigerant R134a Evaporation temp range C 25 to 10 Expansion...

Page 16: ...Compressor overload Electronic driver overheat Programmable running modes Standard Smart Speed Sleep Sleep Energy Saving Slave Setup by default Running mode Standard Speed selection external switcher...

Page 17: ...P 2 000 116 1 15 264 1 64 577 2 34 2 500 142 1 13 330 1 62 712 2 26 3 000 168 1 11 395 1 58 842 2 17 3 500 192 1 09 454 1 54 968 2 07 r p m T evap 25 C T evap 10 C T evap 7 2 C Pe W I A Pe W I A Pe W...

Page 18: ......

Page 19: ......

Page 20: ...technology specialists Today we operate from engineering and manufacturing facilities spanning across three continents FRCC PC 041 A1 02 Danfoss Light Commercial Refrigeration Compressors made by Hua...

Reviews: