Setting up the speed

It is possible to operate the compressor at fixed 
or variable speed under different running modes, 
options and parameters. The electronic driver 
is supplied by the manufacturer with standard 
running mode and external control of the 
speed, with minimum speed of 2,000 rpm. and 
maximum speed 3,500 rpm. Default running 
mode, options and parameters can be changed 
to optimize compressor performance for a given 
appliance, by programming, connecting a PC 
to the SPI by means of the FxC programming 
package provided by the manufacturer upon 
request. Running modes and options are: 

• Standard mode: 

Compressor speed is a fixed programmed 
value or switched externally from programmed 
minimum and maximum value in four steps. 
The switch should be connected to the SPI and 
should remain plugged during compressor 
operation. 

When setting up a fixed speed, maximum speed 
can be limited by the available battery voltage in 
the following way, maximum speed would be: 

· 2,000 rpm when the battery voltage is equal to 
the cut-in voltage. 
· Programmed fixed speed when the battery 
voltage is equal to or greater than the maximum 
nominal voltage (14V, 28V and 42V for 12V, 24V 
and 42V systems respectively). 
· A linear function of the battery voltage in the 
range between the cut-in and the maximum 
nominal voltages. 

This option is particularly useful for eutectic 
plates systems. 

If external switching is programmed, the speed 
is set up by the connection of the SPI connector 
terminals IN1 and IN2 to COM for minimum, 
maximum speeds, and two intermediate 
velocities according to Table 4: 

External speed set up option must be previously 
programmed for external adjustment of its 
minimum (Smin) and maximum (Smax) limits. 

External switching prevents from the possibility 
of setting up the battery protection externally 
using COM, IN1 and IN2 of SPI as defined in point 
5. 

• Smart Speed® mode:

Compressor will run at variable speed at its 
highest performance depending of the current 
thermal load. The speed can be limited by a 
fixed programmed value and even more by the 
available battery voltage as described in standard 
mode. The speed can also be limited by external 
switching in the same way as described in 
standard mode. 

Table 4. External 

selection of the velocity 

0=Open connection  

1=Shortened

Connection to COM

Speed of the motors (rpm)

IN1w 

IN2

0

0

Smin

1

0

Smin+1/3 (Smax-Smin)

0

1

Smin+2/3 (Smax-Smin)

1

1

Smax

11

FRCC.PC.041.A1.02

Summary of Contents for GLT80TDC

Page 1: ...Danfoss Light Commercial Refrigeration Compressors GLT80TDC Direct Current 24 42V Mobile Applications Application guidelines http cc danfoss com...

Page 2: ......

Page 3: ...Wiring and Connections 6 The serial port interface 8 Operating voltage 9 Battery protection system 10 Setting up the speed 12 Programming the electronic driver 13 Protections and alarms 14 Compressor...

Page 4: ...ppliance EIM and making the compressor work in slave mode FDC3 electronic driver includes Smart Speed as programming option which is a plug in system for automatically self adapting compressor speed t...

Page 5: ...been stopped during a certain period of time with an inclination higher than 15 it is strongly recommended to not start up the compressor immediately after coming back to the correct position We recom...

Page 6: ...FUSE MUST BE PLACED BETWEEN THE POLE OF THE BATTERY OR DC POWER SUPPLY AND THE POWER INPUT TERMINAL OF THE ELECTRONIC DRIVER 12V SYSTEMS 30A FUSE 24V SYSTEMS 30A FUSE 42V SYSTEMS 20A FUSE In some spe...

Page 7: ...iagram Fig 2 FDC3 wiring scheme Fig 3 Connection of FDC3 driver to the compressor The FDC3 electronic driver features a terminal board where all connections are made The terminal lay out is described...

Page 8: ...y alarm Set up either the compressor speed or the battery protection level through physical connections between IN1 IN2 and COM Connect the electronic driver as slave to an Electronic Integral Manager...

Page 9: ...is within 33 and 42 4V Special programming option The compressor can be powered by a variable DC source as for instance a photovoltaic panel in which the output voltage strongly depends on the intens...

Page 10: ...0 40 0 2 0 3 0 Special 9 0 40 0 1 0 3 0 Externally using COM IN1 and IN2 of SPI This option prevents from the possibility of setting up the speed externally using COM IN1 and IN2 of SPI as defined in...

Page 11: ...than the maximum nominal voltage 14V 28V and 42V for 12V 24V and 42V systems respectively A linear function of the battery voltage in the range between the cut in and the maximum nominal voltages This...

Page 12: ...Sleep Energy Saving is done in the same way as Sleep Slave mode Under this mode variable speed is controlled by an Electronic Integral Manager of the appliance EIM permanently connected to the electro...

Page 13: ...incompatible with external battery protection step 8 2 7 2 Smart Speed mode Select maximum fixed speed or external switcher connected to SPI and proceed as described in 7 1 1 or 7 1 2 respectively 7 3...

Page 14: ...om the power supply The intervention of the thermostat during the sequence of automatic restart attempts interrupts and resets the sequence The SPI can be configured in a way that a LED can be connect...

Page 15: ...rd ON OFF according with CECOMAF GT 4004 standard Vibrations according with ASTM 5728 Level I standard Application Application MBP HBP A C Refrigerant R134a Evaporation temp range C 25 to 10 Expansion...

Page 16: ...Compressor overload Electronic driver overheat Programmable running modes Standard Smart Speed Sleep Sleep Energy Saving Slave Setup by default Running mode Standard Speed selection external switcher...

Page 17: ...P 2 000 116 1 15 264 1 64 577 2 34 2 500 142 1 13 330 1 62 712 2 26 3 000 168 1 11 395 1 58 842 2 17 3 500 192 1 09 454 1 54 968 2 07 r p m T evap 25 C T evap 10 C T evap 7 2 C Pe W I A Pe W I A Pe W...