Make sure that the mating structure is not damaged. Do not pluck any bores or use at headed
bolts or rods for pushing the electric machine out of the mating structure.
For dismounting the electric machine, follow the Steps below.
on page 38. Dismount the electric machine in reverse order.
1. Prepare the electric machine for lifting, for more information refer to Chapter
on page 31.
Support the electric machine with lifting slings when dismounting.
2. Loosen the mounting bolts. For more information refer to Chapter
page 38.
3. If force is required, use the bores in D-end flange to push the electric machine out from the mating
structure, or use some other method that does not damage the electric machine.
4. Lift the electric machine off. Support the electric machine when lifting.