Insulation resistance test
Do not touch the electric machine during the insulation resistance check. Discharge the machine afterwards.
Measure the insulation resistance of the electric machine before the installation of the electric
machine. Because of the structure of the electric machine it is possible that the stator is damaged
during the installation. The reference value of 150 MΩ must be exceeded in room temperature.
Contact Danfoss representative if the reference value is not exceeded.
Mechanical installation
Allowed mounting positions
EM-PMI375-T200 uses the mounting option 1. See Figure below.
EM-PMI375-T500 and EM-PMI375-T800 use the mounting option 1 as standard, but with grease
lubricated bearings they use mounting option 2. See Figures below.
EM-PMI375-T1100 uses mounting option 2. See Figure below.
Figure 17. Allowed mounting positions, mounting option 1
X = 30°
EM-PMI375
6. Installation
34 |
©
Danfoss | Produced By: Danfoss Power Solutions | January 2019
| BC265856307805en-000105