Summary of Contents for DEVIreg Multi

Page 1: ...www DEVI com Installation Guide DEVIreg 530M Electronic Thermostat...

Page 2: ...and a wire sensor to measure and control the desired floor temperature It can be either flush mounted standard or surface mounted using special box The thermostat has a button for adjusting the tempe...

Page 3: ...ts NTC 15 kOhm at 25 C Default Sensing values 0 C 20 C 50 C 42 kOhm 18 kOhm 6 kOhm Hysteresis 0 4 C Ambient temperature 10 to 30 C Temperature range 15 35 C with floor sensor only Cable specification...

Page 4: ...a wooden floor or similar material always use a floor sensor and never set the maximum floor temperature to more than 35 C Please also note the following The installation of the thermostat must be don...

Page 5: ...e accurate temperature control and is recommended in all floor heating applications and mandatory under wooden floors to reduce the risk of over heating the floor Place the floor sensor in a conduit i...

Page 6: ...40 50 Press the release tab in the bottom of the thermostat using a flat object Carefully detach the front cover Carefully detach the frame 2 Connect the thermostat according to the connection diagra...

Page 7: ...s The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector Note Always install the floor sensor in a conduit in the floor 3 Moun...

Page 8: ...ng The floor temperature is measured where the floor sensor is placed The temperature of the bottom of a wooden floor can be up to 10 degrees higher than the top Floor manufactures often specify the m...

Page 9: ...oximate setting for 25 C floor temperature 0 05 8 mm HDF based laminate 800 kg m3 28 C 0 10 14 mm beech parquet 650 800 kg m3 31 C 0 13 22 mm solid oak plank 800 kg m3 32 C 0 17 Max carpet thick ness...

Page 10: ...dance with the instructions the fault is submitted to the installer or the seller without undue delay and proof of purchase is provided Please note that the WARRANTY CERTIFICATE must be filled in stam...

Page 11: ...ation Guide WARRANTY CERTIFICATE The DEVIwarranty is granted to Address Stamp Purchase date Serial number of the product Product Art No Connected output W Installation Date Signature Connection Date S...

Page 12: ...DEVIreg 530M Installation Guide 12...

Page 13: ...DEVIreg 530M 13 Installation Guide 5 Disposal Instruction...

Page 14: ...DEVIreg 530M Installation Guide 14...

Page 15: ...DEVIreg 530M 08096180 AN415537660567en 010101 Produced by Danfoss 05 2022 Danfoss A S Nordborgvej 81 6430 Nordborg Syddanmark Denmark...

Page 16: ...d DEVIreg 530M 140F1101 Thermostat Floor Sensor 220 240V 50 60Hz 5 C to 45 C 15A 3450W 230V IP 31 Product documentation Designed in Denmark for Danfoss A S 08096180 5 703466 210406...

Reviews: