CFRC REMOTE CONTROLLER
6
GB
4. Mounting
The Remote Controller has been installed – fi g. 2
When the Remote Controller has been installed to the Master
Controller (see chapter 2), it can be mounted on the wall by means of
the back plate/docking station . The Remote Controller is powered
by two AA Alkaline 1.5V batteries.
• Before you place the back plate/docking station on the wall, verify
the transmission to the Master Controller from the desired location
by carrying out a link test (see chapter 3).
• Mount the back plate/docking station on the wall with the screws
and wall plugs .
• Place the Remote Controller in the docking station .
Note: To extend the transmission range of the CF2 system, up to three
Repeater Units can be installed in a chain – see fi g. 4.
5. Menus
Note: When the back light in the display is out, the fi rst touch of a button
only activates this light.
5.1 Rooms
From the start-up screen, activate the:
Rooms
menu to access a list of all the rooms in the system. Select the
desired room with OK to enter the screen for that room. Here you can
see information about the set and actual temperatures:
: Indicates that this room is included in an ongoing time
programme (see chapter 5.2)
: Indicates that the Room Thermostat is running low on
battery
: Indicates that the value set on the Room Thermostat is beyond
the max./min. limitations set by the Remote Controller
: Indicates that the set temperature is above the actual
temperature
: Indicates that the set temperature is below the actual
temperature