Ordering

Accessories

Transformer module 230 V / 115 V to 24 V

AK-PS 075

18 VA

Supply 

080Z0053

Type

Function

Application

Language

Code no.

AK-PI 300

Protocol interface

Intermediary link between system manager and units with 

Daikin data communication 

English, German, 

080Z8526

Data

Supply voltage

24 V a.c.  +/- 20%

Power consumption

AK-PI 300

12 VA

Ambient temperature

During transport

-40 to 70°C

During operation

-20 to 55°C , 
0 to 95% RH (non condensing) 
No shock influences / vibrations

Enclosure

Material

PC / ABS

Enclosure

IP10 , VBG 4

Mounting

For mounting on wall or DIN rail

Weight

Approx.  600 g

Approvals

EU low voltage directive and EMC require-
ments are complied with

LVD tested according to EN 60730
EMC tested
Immunity according to EN 61000-6-2
Emission according to EN 50081-1

UL 873, 

UL file number: E166834

Summary of Contents for AK-PI 300

Page 1: ...Protocol interface AK PI 300 Manual...

Page 2: ...outdoor unit is connected via a Comm box Principle The link between the system manager and the AK PI 300 is via a TCP IP In this very simple connection the two units can be connected to each other vi...

Page 3: ...ress can be viewed in the IP list Up to two PI units can be connected to the system manager which is master i e has address 1 You set the network address on the front of the system units and on the fr...

Page 4: ...ted to a router or to a switch A dynamic or static IP address is used here 2 Setting a Router Dynamic There are no settings in the router Static A static address range must be set in the router b AK S...

Page 5: ...in the next point Perform the first scan 1 Start the scan function in the system manager wait for the results the controllers on the LON and MODBUS communication will now be located and visible in th...

Page 6: ...it is set with the 2 subsequent ones The units on an RTD network must not have an address that coincides with these 3 addresses Requirements and terms Principle Network addresses Here is a small summa...

Page 7: ...manager that AK PI 300 is connected to The status of the alarm transmission Date and time The quality of the Daikin communication signal The configuration display gives access to the following The con...

Page 8: ...ansformer module 230 V 115 V to 24 V AK PS 075 18 VA Supply 080Z0053 Type Function Application Language Code no AK PI 300 Protocol interface Intermediary link between system manager and units with Dai...

Reviews: