42
Display Intensity / din
ERC 102 can have its display intensity (brightness) set in one of two ways:
A) with a Danfoss ambient light sensor attached, the brightness of the display is
adjusted automatically according to the ambient light level (see the Assignments
section)
B) when no ambient light sensor is attached, the display intensity can be set to
a fixed intensity .
Both options are on a scale of 1 to 10, where 10 is the brightest .
7.11 Assignments /
ASi
ERC menu
code
Default
Min
Max
Unit
Conv
Unit
Scale
Default Access
Shop Ser OEM
Assignments
ASi
S1 Config
S1C
Stn
Stn
dig
no
-- -- RW
S2 Config
S2C
Stn
Stn
dig
no
-- -- RW
S3 Config
S3C
Stn
Stn
dig
no
-- -- RW
S1 Application
S1A
SCo
nC
doo
no
-- -- RW
S2 Application
S2A
nC
nC
doo
no
-- -- RW
S3 Application
S3A
nC
nC
doo
no
-- -- RW
DI Config
diC
dio
doC
dio
no
-- -- RW
DO1 Config
o1C
CoP
CoP
HEt
no
-- -- RW
DO2 Config
o2C
dEF
0
Lig
no
-- -- RW
DO3 Config
o3C
FAn
0
Lig
no
-- -- RW
DO4 Config
o4C
Lig
0
Lig
no
-- -- RW
Button 1 Short Config
b1C
noP
tP
noP
no
-- -- RW
Button 1 Long Config
b1L
PoF
tP
PoF
no
-- -- RW
Button 2 Short Config
b2C
dEF
tP
noP
no
-- -- RW
Button 3 Short Config
b3C
tP
tP
noP
no
-- -- RW
Button 3 Long Config
b3L
ECo
tP
PoF
no
-- -- RW
Button 4 Short Config
b4C
tn
tP
noP
no
-- -- RW
Button 4 Long Config
b4L
Lig
tP
PoF
no
-- -- RW
Pass-word level1
PS1
0
0
999
no
RW RW RW
Pass-word level2
PS2
0
0
999
no
-- RW RW
Pass-word level3
PS3
0
0
999
no
-- -- RW
Cabinet Light Control
Source
CLC
Lig
Lig
LEC
no
-- -- RW
Door close delay
dCd
0
0
300
no
Sec
1
-- -- RW
Light off delay
Lod
0
0
300
no
Sec
1
-- -- RW
Danfoss ERC 102
Hold 3 sec: Menu
1 Click: Variable direct function, e.g.ECO/Night mode
1 Click: Variable direct function, e.g. light
Sub function: Up
1 Click: Temperature setpoint
Sub function: Down
Sub function: Back
Sub function: OK
ERC Front and Button Functionallity:
1 Click: Temperature setpoint
For more details on how to set parameters
- see chapter 6 .
ERC
102 Reference manual – 7 PARAMETERS