44
8. TECHNICAL SPECS
ERC 102 user manual – 8 TECHNICAL SPECS
78,25 mm
Dimensions:
Front mounting
Rear mounting
78,25 mm
82,25 mm
36,5 mm
28,5 mm
30 mm
28 mm
71 mm
71 mm
Power Supply
100 V AC - 240 V AC, switch mode power supply
Rated Power
Average 0 7 W
4 Inputs: 3 Analogue & Digital, 1 Digital; user specific assignment
Input
• Air / Evaporator / Condenser
• Door sensor: All types, user specific
• Light sensor: Danfoss ECO light sensor
• DP for remote communication
Output
UL60730
EN60730
DO1
(Compressor relay):
120 V ac: 16A resistive/ FLA16 / LRA72 .
240 V ac: 10A resistive /FLA10 /LRA60 .
16(16)A
DO4
8 A resistive, FLA2/ LRA12, TV-1
8 A resistive, 2(2) A
DO5
FLA2/ LRA12, TV-1
8 A resistive, 2(2) A
DO6
FLA2/ LRA12, TV-1
8 A resistive, 2(2) A
Max 10 A total DO4-6
Probes
Danfoss NTC sensors and Danfoss ECO accessories (300 - 3,000 mm)
Connectors
Modular connector system for OEM customers, with optional output screw terminal adapter; Input connector
type: Rast2 5 Edge connectors; Output connector type: RAST 5 Standard
Programming
Programming with Danfoss ERC docking station, integrated system
Assembly
3 types for all controls: Front mounting (patents pending); brackets; fully integrated solution (requires OEM
specific design of mounting hole)
Display
LED display, 3 digit, decimal point and multi functionality icons; °C/F scale
Keypad
4 buttons (integrated IP65 design), 2 left, 2 right; user programmable
Operating Conditions
0 °C to 55 °C, 93% rH
Storage Conditions
-40 °C to 85 °C, 93% rH
Range of Measurement -40 °C to 85 °C
Protection
front: IP65/rear: water and dust protection corresponds to IP31, accessibility of connectors limit rear part rating to IP00
Environmental
Pollution degree II, non-condensing
Resistance to heat & fire Category D (UL94-V0)
EMC category
Category I
Operating Cycles
Compressor relay: more than 175,000 at full load (16A(96A))
Approvals
Note:
These approvals
are only valid when
using the accessories
listed in this document
R290/R600a : EN/IEC 60079-15:2005
Glow wire according to EN/IEC 60335-1
IEC/EN 60730
UL60730
NSF
CQC
GOST R 60730