Configure the Drive with Switches
04/06
Danaher Motion
20 Rev
D
M-SD-7AC-01
3.7
E
NCODERLESS
S
TALL
D
ETECTION
™
The P70360 drive is uniquely designed to sense the motor shaft position at
all times. The drive monitors the commanded position and compares it to
the actual position. As with any 2 phase step motor, when the shaft position
and commanded position are greater than two full steps apart a stall will be
detected and the drive will fault.
Stall Detection
S2-12
ON=Enabled