Danaher Motion
04/06
Configure the Drive with Switches
3.
CONFIGURE THE DRIVE WITH
SWITCHES
NOTE
The drive is configured by either using P7000Tools or
the switches on the top of the drive. The instructions
that follow detail how to configure the drive using the
switches.
3.1
M
OTOR
S
ELECTION
Configure the drive for a motor type via switch settings on the top of the
drive. Valid settings are:
MOTOR S1
S2
MOTOR S1
S2
USE
GUI
0 OFF
K31HRLG 8 OFF
T21NRLC
1 OFF
K32HRLG 9 OFF
T22NRLC 2
OFF
K33HRLG A
OFF
T23NRLC 3
OFF
K34HRLG B
OFF
N31HRLG 4
OFF
N41HRLG C
OFF
N32HRLG 5
OFF
N42HRLG D
OFF
N33HRLG 6
OFF
K41HRLG E
OFF
N34HRLG 7
OFF
K42HRLG F
OFF
NOTE
For non-system motors, configure the drive with the
P7000Tools GUI Wizard. The motor inductance range
for the 320 VDC bus is 50 – 200 mH. The motor
inductance range for the 160 VDC bus is 5 – 30 mH.
Motor type zero is used for non-system motors.
Motor types 16-31 (not shown) are reserved for
factory- configurations.
Using incorrect settings results in zero current (motor
will not operate).
If you cange the motort type, you MUST cycle power to
the drive for the changes to take effect.
M-SD-7AC-01 Rev
D
17