Danaher Motion
04/06
Getting Started
1.4
S
PECIFICATIONS
NOTE
Unless otherwise specified, the specifications are
worse-case limits and apply over the specified
operating ambient temperature and over the specified
operating line voltage.
1.4.1 DRIVE
POWER
Specification P70360
Max Output Current (0-40
°
C)
2.5 A
RMS
Max Output Power 240 or 120 VAC
350 W
RMS Line Current at 3.5 A Motor Current
240 VAC 1 phase
1.5 A
RMS
120 VAC 1 phase
3 A
RMS
Power Dissipation at 3.5A
15 W
Motor Inductance Range with 320 VDC bus
50-200 mH*
Maximum Motor Cable Length (24 AWG)
20 m
Input Voltage Range
120/240 VAC Input (Nominal Bus Voltage)
(50/60 Hz)
320 VDC**
Bus Under Voltage Fault
130 VDC
Bus Over Voltage Fault
440 VDC
Bus Regen Voltage
420 VDC
Inrush Current & Fusing
Peak Current
30 A
Inrush Pulse Width
4 ms
Recommended Fusing
7 A Slow Blow
5 VDC Internal Supply
200 mA
Time delay for "reduced idle current" to return to
the system's "full current"
< 1 ms
(typ)
*7-30 mH for 160 VDC bus
**Drive is also capable of 160 VDC bus
M-SD-7AC-01 Rev
D
3