Danaher Motion
04/06
Troubleshooting
M-SD-7AC-01 Rev
D
39
5. TROUBLESHOOTING
5.1
C
OMMON
P
ROBLEMS
Problems Possible
Fixes
Motor spins in wrong
direction
Reverse wires on one phase. Change direction
polarity using P7000Tools
Motion Profiles in table will
not execute
The P7000 Drive is the SDN version not the PNN
version,
Drive Overheats
Lower ambient temperature. Provide fan cooling.
Reduce system throughput.
5.2
S
TATUS
D
ISPLAY
There are 7 faults that may occur with the P7000 drive. The fault output
latches when they occur. Determine the type of fault by viewing the front
panel or through the serial port. The front panel LED turns red and blinks
according to the table below.
Blink Code
Stall 1
Over Current
2
Over Voltage
3
Drive Over Temp
4
System Error
5
Under Voltage
6
EPROM Checksum
7
The blinking continues until the drive is reset by one of the following
methods:
Power Cycle
GUI Control
Fault Reset (Configurable General Purpose Input)