Serie "EUR7"
Pagina A - 18
Rev. M - 01
The general test cycle will begin instead when the
3
key is kept press for about one second; during this
cycle, the vending machine will carry out a sales cycle in sequence for each gearmotor detected by the
self-learning procedure, starting from the current motor up to the last motor of the vending machine. In the
event of a defect on one of the motors, the test will be interrupted and the relative error message
displayed.
The general test cycle will be interrupted when keeping any key pressed until the end of the sales cycle of
the current motor.
Press the 6 key to exit the submenu.
>
M
OTOR
V
ERIFY
:
Select this item to perform a quick check of the condition of the motors.
This function does not change the vending machine configuration detected during the self-learning
procedure; it simply limits itself to comparing the current condition of the motors with that of the last self-
learning procedure performed.
[Where x.x scrolls the motors in sequence]
If errors should be detected during the check, the check itself stops and the following message appears:
Where “
xxxxxx
” is the detected error. See the “
Installation and service
” manual, "
Problems and relative
solutions
” chapter, “
Motor anomaly messages
” section for the list of anomalies and relative solutions.
From these error conditions it is possible to make the check sequence continue by pressing the
3
key, or
end it with the
6
key.
One of the following messages will appear at the end of the check sequence:
This means that anomalies and/or differences between the current configuration and the one detected
during the last self-learning procedure have been detected; XX indicates the number of the currently
recognised motors.
This means instead that anomalies and/or differences between the current configuration and the one
detected during the self-learning procedure have not been detected; XX indicates the number of the
recognised motors.
In the event o
f “Check OK”, at the end of the motor check cycle the vending machine‟s original
configuration is completely restored and the out of orders reset.
N.B.: at each check the motors rotate just a few degrees; therefore, repeating the check several times in
succession, the motors could lose alignment; we therefore recommend realigning the motors, for example
by carrying out a manual motor test, as described previously in this manual.
Check OK
Conn. motors: XX
Check incorrect
Conn. motors: XX
Error
xxxxxx
Programming
Diagnostics
Motor Verify
->->->->
Motor : x.x
3
3