![damian SNACK EUROPA Installation And Service Download Page 29](http://html.mh-extra.com/html/damian/snack-europa/snack-europa_installation-and-service_504550029.webp)
Serie "EUR7"
Pagina A - 11
Rev. M - 01
>
M
AXIMUM CREDIT
:
To set the maximum credit value accepted by the MDB payment system. When the credit in the vending
machine reaches this value, the machine no longer accepts coins or banknotes.
Settable values: 0 ÷ 65535 (independent of the position of the comma, e.g. with 2 decimals the maximum
credit is 655.35). If set to 0, this control is disabled.
[ Default: 0 ]
>
C
OIN RETURN PARAMETERS
:
If there is an MDB coin return payment system installed in the vending machine, selecting this function it
will be possible to set the following operating parameters for it:
»
C
OIN MINIMUM TO INDICATE NO CHANGE AVAILABLE
(Visible and programmable only if „MDB coin return‟ payment system installed)
To set the minimum value of the coins that must be present in each individual tube of the MDB coin box
below which the vending machine indicates no change available.
Settable values:
0
÷ 15
.
[ Default: 5]
»
C
OIN MINIMUM IN TUBES TO GIVE CHANGE
:
(Visible and programmable on
ly if „MDB coin return‟ payment system installed)
To set the minimum value of the coins that must be present in the tubes in an MDB payment system
below which the vending machine does not give change.
Settable values:
0
÷ 5
.
[ Default: 2 ]
»
C
OMPULSORY SALE
:
(Visible and programmable only if „MDB coin return‟ payment system installed)
If Enabled, the MDB payment system does not give change before a sale, to prevent it from being used
as a coin changer. Settable values:
„
Disabled‟
(OFF), „
Enabled‟
(ON).
[ Default:
Disabled ]
»
M
ANUAL EMPTYING OF THE COIN TUBES
:
(Visible and programmable only if „MDB coin return‟ payment system installed)
If activated it enables the manual emptying of the coin tubes through the pushbuttons on the MDB
payment system. Settable values:
„
Disabled‟
(OFF), „
Enabled‟
(ON).
The emptying of the coin tubes performed by the programming is carried out as described further on:
[ Default:
Disabled
]
Programming
MDB parameter
Maximum credit
Current value
3
Programming
MDB parameter
Coin retn.param.
->->->
MinTube NoChange
Current value
3
3
Programming
MDB parameter
Coin retn.Param.
->->->
Min. coins tubes
Current value
3
3
Programming
MDB parameter
Coin retn.Param.
->->->
Obligatory sale
Current value
3
3
Programming
MDB parameter
Coin retn.Param.
->->->
Enab.Man.Dispens
Current value
3
3