Serie "EUR7"
Page 11
Rev. M - 01
Message
code
Message text
Problem description / solution
OFF L10… FTCA vending sensor error –
These error messages may appear when the vending machine is turned
on or right before a sale.
OFF L10a
OFF L10b
OFF L10c
FTCA sensors OFF
(Chk cable, Chang)
– FTCA bars not connected
- Check the condition of the wiring and of the connections of the FTCA bars (3)
and replace wiring if necessary.
- If the problem persists, replace the FTCA bars (3) one at a time, starting from the
one on the right.
- If the problem is not resolved, check CPU card operation.
OFF L10e
(Check LeftSensor) - Left hand FTCA bar error
- Check the condition of the wiring and of the connection of the left hand FTCA bar
(3) and replace it if necessary.
- If the problem is not resolved, check CPU card operation.
OFF L10f
(Check RightSens.) - Right hand FTCA bar error
- Check the condition of the wiring and of the connection of the right hand FTCA
bar (3) and replace it if necessary.
If the problem is not resolved, check CPU card operation.
OFF L10g
(High Light) - FTCA bars blinded error
- Perform the vending sensor test.
- Attenuate the possible source of external light that bothers the FTCA bars.
- If the problem persists, replace the FTCA bar/s (3).
OFF L10h
(Low Light ) - FTCA bar darkened error
- Perform the vending sensor test.
- Check the state of cleanliness of the FTCA bars (3), eliminating any elements
that might obstruct passage of the light emitted by the LEDS.
- If the problem persists, replace the FTCA bar/s (3).
OFF L13… Sliding anti-theft panel errors.
These error messages concern failures of the sliding anti-theft panel
(10) closing/opening system.
For
a quicker check, perform the “Sliding door test” as explained further on.
OFF L13a
Sliding Panel
(S.D. Mot. Fault) - Sliding panel motor short-circuited
- Check the operation of the sliding panel motor (11) and the relative wiring; replace
it if necessary.
OFF L13b
(SD Mot. Disconn.) -
Sliding panel motor disconnected
- Check the motor (11) of the sliding panel (10) and the relative wiring. Replace it if
necessary.
OFF L13e
(Lock Pos.TimeOut)
– Sliding panel motor movement error
At the end of an opening / closing cycle, the sliding panel does not close completely
or is not detected to be closed, or not open completely or is not detected to be open;
You are trying to make the sliding panel (10) work but the motor (11) idles or is
blocked.
- Check that the sliding panel (10) can slide freely, that the guides are clean and that
there is nothing preventing complete closing.
- Check that the motor gear (11) works correctly.
- Check the operation of the opening microswitch (13) and the relative wiring.
Replace it if necessary.
OFF L13k
OFF L13l
(Levers not down)
– Error movement locking lever product removal door
During a cycle of opening / closing of the sliding panel (10) is not detected lowering
of the locking levers (5) of the door product.
- Check that the two lock levers (5) of the door product can move freely.
- Check that the two microswitches (6) of lock levers are correctly connected and
adjusted; make sure that the wiring is in good condition and replace them if
necessary..