background image

 

Serie "EUR7"

 

 
 

 

Pagina A - 21 

 

Rev. M - 01 

S

UMMARY TABLE

:

 

 

 

 

          

(*) Memorandum to be filled out after the programming under way

 

Menu 

Parameter 

Meaning 

Min-Max 

Default 

Adjusted 

to (*)

 

General Param’s

  Language 

Message language 

 

Italian 

 

General Param’s

  LCD contrast 

LCD contrast setting   

40 

 

General Param’s

  Operating mode 

Operating mode 

 

MDB 

 

General Param’s

  DDD DD/mm hh:mm 

Clock setting 

 

General Param’s

 

DateTime Dsp 
Enable 

Clock enable 

Enabled - 
Disabled 

Enabled 

 

General Param’s

  SaveMode delay 

Activation delay in SaveMode 

0 ÷ 120 minutes 

 

General Param’s

  Light in SaveMode 

Light intensity in SaveMode 

0 ÷ 100% 

100% 

 

General Param’s

 

NightMode 
timetable 

NightMode Activation 
Timetable 

 

19:00÷7.00 

 

General Param’s

  NightMode Light 

Light intensity in NightMode 

0 ÷ 100% 

100% 

 

General Param’s

  NightMode temp. 

Temperature setting in 
NightMode 

0 ÷ 50 °C 

 

General 

Param’s

 

Refrigerator 
operation 

Refrigerator Operation 

 

Aut. 

 

General Param’s

  FTCA enabling 

Vending sensor enabling 

0)Disabled, 
1)Enable Nostep, 
2)3step 

2) 

3step 

 

General Param’s

  FTCA max 3 sel. 

FTCA max 3 selections 

Enabled - 
Disabled 

Enabled 

 

General Param’s

  Decimal point 

Decimal point position 

0 ÷ 3 

 

General Param’s

  Code Mode 

Internal code software 

Read only

 

General Param’s

  Software versions 

Displays software versions 

 

General Param’s

  Default P. Reset 

Card reinitialisation 

Password required

 

General Param’s

  Protected param. 

Protected parameters 

Password required

 

 

Reset Temp. 

--- 

Reinitialise overtemperature times 

 

 

 

 

 

 

Price management  Price-A N.:xx 

Value of each of the 44 
associable „A‟ bracket prices 

0 ÷ 635.35 

2.00 

----

 

Price management  Price-B enabling 

Enabling „B‟ price bracket 

Enabled - 
Disabled 

Disabled 

 

Price management  Price-B N.:xx 

Value of each of the 44 
associable „B‟ bracket prices 

0 ÷ 635.35 

2.00 

----

 

Price management  Enabl. Dir. Sel. 

Enabling direct selections 

0)OFF Disable, 

1)ON Manualreset, 
2)ON Auto Reset 

Disabled 

 

Price management  Drawer L-C 

Direct selection association 

S1-S2-S3 

 

 

Price management  Drawer L-C 

Price associated with drawer 
(Line) 

L

, (column) 

C

 

0 ÷ 44 

01

 

----

 

Price management  Enable Price Dsp 

Display of the selling price 

Enabled - 
Disabled 

Enabled 

 

 

Executive 
parameters 

Min. coin values 

Coin scaling factor 

0 ÷ 1000 

000.01 

 

 

MDB parameters 

Maximum credit 

Maximum accepted credit 

0 ÷ 635.35 

 

MDB parameters 

MinTube NoChange 

Minimum coins to 

turn “

no 

change

” indicator light on 

 

 

MDB parameters 

MinTube Change  

Minimum coins for giving 
change 

 

 

MDB parameters 

Obligatory Sale 

Compulsory sale 

Enabled - 
Disabled 

Disabled 

 

MDB parameters 

Enab. Man. 
Dispens 

Manual emptying of the coin 
tubes 

Enabled - 
Disabled 

Disabled 

 

Summary of Contents for SNACK EUROPA

Page 1: ...X INSTALLATION AND SERVICE PROGRAMMING This manual is for skilled service personnel only DAMIAN S R L VIA RAGAZZI DEL 99 N 30 21053 CASTELLANZA VA ITALY Rev M 01 Vers Software 0 5b or follow ...

Page 2: ...Serie EUR7 Page 18 Rev M 01 ...

Page 3: ...o model The intended use for EUR7 series SNACK EUROPA automatic spiral vending machines consists of automatically distributing solid products or products in solid package pre packaged foods snacks bottled drinks etc and non food items For food products make sure that the package is whole and that the products are in a good state of preservation in conformity with the current applicable regulations...

Page 4: ...T TO MALFUNCTION Characteristics Variation EUR7B x xx A EUR7B x xx R EUR7P x xx S EUR7L x xx L Power supply Voltage 220 230V Frequency 50Hz Rated power 160 W 460 W 490 W 490 W Max Rated power 260 W 620 W 650 W 650 W Protection IP24 Only suitable for covered and protected places where it cannot be rained on or sprinkled by water jets Refrig System version Assente Standard Super Super L Minimum inte...

Page 5: ... make sure that they do not play with the vending machine Before checking any electrical part move the main switch of the vending machine See Figure 2 to the OFF position UNPACKING Unpack the vending machine as follows Cut the clear plastic wrapped around the packing box and remove the various protective corners Free the keys that are tied together with the power cord on the lower rear part of the...

Page 6: ...f them rest correctly on the ground When the vending machine is not levelled properly it can be difficult to close the door With the wall anchoring bracket kit accessory it is possible to anchor the vending machine to the wall with two special spacers See Fig 4 as follows Screw the two wall anchoring brackets on the top of the vending machine see figure with the screw from above and a nut from ins...

Page 7: ...killed service personnel Before all operations on the power cord make sure that the power supply plug is disconnected from its outlet Remove the rear grille of the cabinet by unscrewing its fixing screws remove the cable gland from the grille open the cable gland and remove the cable Disconnect the cable socket from the electrical box and remove the cable to be replaced Repeat the operations descr...

Page 8: ...ration of the executive payment systems Connect the Molex 15 pin female power connector of the vending machine to the corresponding connector on the payment system Refer to the payment system documentation Connect the serial connector of the payment system to the CPU card 2 using the special adapter cable being careful to connect the adapter cable on the proper connector See Figure 5 Turn the vend...

Page 9: ...el rack 3 FTCA sensor bars 10 Anti theft sliding panel 18 Sliding panel motor pinion 5 Levers for locking the Push door 11 Sliding panel motor 6 Two microswitches of the Push locking 13 Beginning end stroke microswitches 3 2 10 FIGURE 5 FTCA connector KEYBOARD connector DISPLAY connector EXECUTIVE connector MDB connector PS1 11 17 18 13 6 5 5 7 ...

Page 10: ...e time B is prolonged by a value equal to the one set in the Restocking time C parameter Each time it is turned back on if the internal temperature exceeds the Safety temperature A but the conditions for generating the ERR L09 error have not occurred see above the following message will appear on the display for approx 15 sec XXX Missing minutes YY Y Internal temperature ZZ Z Safety temperature by...

Page 11: ... probe has been replaced the problem is repeated the fault might be due to the CLP1 power board located in the electrical box OFF L02 Temperature probe 2 error These messages indicate a problem with the probe that measures the temperature of the refrigeration unit evaporator This probe is located in the refrigeration unit located under the central plane of the machine The refrigeration unit must b...

Page 12: ...f the problem persists replace the FTCA bar s 3 OFF L13 Sliding anti theft panel errors These error messages concern failures of the sliding anti theft panel 10 closing opening system For a quicker check perform the Sliding door test as explained further on OFF L13a Sliding Panel S D Mot Fault Sliding panel motor short circuited Check the operation of the sliding panel motor 11 and the relative wi...

Page 13: ...xx Short Circuit NR The motor is short circuited Check the good condition of the motor itself Check that the motor and its connections are not wet Check the connections and that the motor wiring is not short circuited Try replacing one at a time the motor the CPU card the drawer and cabinet wiring Motor xx blocked R The motor is blocked or absorbs too much current Check the correct assembly of the...

Page 14: ...ou have made the correct selection Carry out the Motor Verify procedure found in the diagnostic menu Carry out a new self learning procedure of the motors through the reset of the circuit board If the motor is not recognised during the self learning procedure see the relative error further on WHEN MAKING A SELECTION SELECTION X X OUT OF ORDER IS INDICATED If some selections are out of order indica...

Page 15: ...er too high nor too low referring to the programming sheet Check that the internal air circulation fan works correctly Check that the refrigeration unit compressor works and that the cooling fan located between the compressor and the condenser of the refrigeration unit works properly If the compressor does not start working when the LED on the card indicates that it is activated check and if neces...

Page 16: ...6 3 6 3 A delayed 250 V General 24 28V The vending machine does not work C F3 5x20 T6 3 6 3 A delayed 250 V General 230V The vending machine does not work D F4 5x20 T6 3 6 3 A delayed 250 V General 230V The vending machine does not work E F5 5x20 F1 1A rapid 250 V CPU power supply The vending machine does not work the display does not turn on Figure 7 E Press to enter into programming Press to can...

Page 17: ... that it turns on again only after it has been closed completely SLIDING PANEL CHECK Sliding panel 10 operation can be checked by performing a door closing and opening test see programm diagnostics Sliding panel test CHECK CLEANING OF FTCA VENDING SENSORS To clean the LED barriers of the FTCA system 3 which are protected hidden by the sliding anti theft panel during normal operation it is necessar...

Page 18: ...anctions provided for by the regulations in force 1 In the European Union If the equipment is marked on the outside with this symbol it should not be disposed of with normal household waste Contact your local dealer for further information regarding disposal 2 In countries outside the EU If you wish to get dispose of this product please contact the local authorities for information on the correct ...

Page 19: ...ttachment A PROGRAMMING SHEET This attachment is an integral part of the manual and must remain with it DAMIAN S R L VIA RAGAZZI DEL 99 N 30 21053 CASTELLANZA VA ITALY Rev M 01 Vers Software 0 5b or follow ...

Page 20: ...gain from the first parameter When the message relative to the desired parameter appears press the 3 Enter key to confirm TO CHANGE THE PROGRAMMED VALUE OF THE SELECTED PARAMETER If appears on the second line followed by the current value Using the keyboard write the desired value or press the 1 A key to increase or the 2 C key to decrease the current value Press the 3 Enter key to confirm and ret...

Page 21: ...bled ENERGY SAVING PROGRAMMING To activate and set the parameters of the energy saving functions which are only available if the vending machine has the Vivilight Kit installed Energy Saving allows activating two separate energy saving functions Save Mode function Kicks in after a programmed vending machine inactivity time and reduces the electrical consumption of the vending machine working for e...

Page 22: ...Night Mode function Set the times to 00 00 00 00 to disable the function Default 19 00 07 00 NIGHT MODE LIGHT INTENSITY Visible and programmable only with Vivilight Kit installed This parameter allows setting the luminous intensity in of the LED lamps that light up the display window when the Night Mode function is activated Settable values 0 100 Default 100 NIGHT MODE INTERNAL TEMPERATURE SETTING...

Page 23: ...ail or if the 3 step function is not active the vending machine still keeps the credit stored in memory and allows a new selection to be made When this function is selected it will be possible to set the following parameters of the FTCA function ENABLING FTCA VENDING SENSORS To activate operation of the vending sensors that check passage of the product Settable values 0 Disabled FTCA deactivated 1...

Page 24: ...earning procedure will start over from the beginning A This message appears on the display after selecting the desired language press 3 to confirm B This message appears on the display Check that the number of connected motors corresponds to those actually present in the vending machine if there is a discrepancy proceed as described in the installation and service manual in the Answers to problems...

Page 25: ... there are two refrigerator probes connected the following message will appear when the 3 key is pressed or It is possible to confirm FOOD Snack mode or alternatively select the Drink Snack mode or OFF Management of the safety temperature is activated when FOOD Snack mode is selected the following message will appear when the 3 key is pressed The safety temperature value is displayed with the poss...

Page 26: ... For the EUR7 vending machines it is possible to manage a second bracket of another 44 price lines the B price bracket to be used for example for sales made with payment systems to which we wish to assign dedicated prices i e Cashless or RFID systems The prices of the B bracket will automatically be associated with the same selections associated with the A bracket For example if price line 1 of th...

Page 27: ...m and FTCA system installed Settable values 0 OFF Disabled Selling direct selections Disabled 1 ON ManualReset Selling direct selections Enabled with manual reset Each time it is turned back on is required the manual reset of empty 2 ON Auto Reset Selling direct selections Enabled with auto reset Each time it is turned back on is automatically run the reset of empty Default Disabled Enabling the m...

Page 28: ...tion scroll through the price lines with the 1 and 2 keys after having selected the desired one confirm it with the 3 key DISPLAY OF THE SELLING PRICE Enables the display of the selling price of the product requested by the customer at the time of the sale Settable values Enabled ON displayed Disabled OFF displayed Default Enabled EXECUTIVE PAYMENT SYSTEM PARAMETERS Visible and programmable only w...

Page 29: ... installed To set the minimum value of the coins that must be present in the tubes in an MDB payment system below which the vending machine does not give change Settable values 0 5 Default 2 COMPULSORY SALE Visible and programmable only if MDB coin return payment system installed If Enabled the MDB payment system does not give change before a sale to prevent it from being used as a coin changer Se...

Page 30: ...oin disabled Press the 3 key to enable disable the coin Press the 4 key to manually empty from 1 to 9 coins from the indicated tube Note 1 The value of the coins recognised by the payment system depends on the system itself refer to the relative documentation Note 2 With some MDB payment systems the parameter indicating the quantity of coins present could be handled by the payment system itself Re...

Page 31: ...ble disable the token Note 1 the meaning and operation of the recognition security level depends on the payment system refer to the relative documentation CASHLESS If one or more cashless payment systems are installed in the vending machine it is possible to select the price bracket to be associated with these systems CASHLESS N 1 PRICE BRACKET ASSOCIATION Visible and programmable only if a Cashle...

Page 32: ... This parameter allows setting the internal temperature of the vending machine when the Night Mode function is activated Settable values 0 50 C The refrigerator temperature raising function is deactivated during the Night Mode period if the parameter is set to 0 Zero or to a value below the one set as standard internal temperature Set Std Temp 1 in the Refrig Param s menu This parameter can also b...

Page 33: ... PASSWORD CODE RESET EVA DTS To reset the Security and Passcode codes foreseen by the DDCMP protocol EVA DTS to prevent anyone from being able to access and download the data relative to the vending machine proceeds using an IRDA handheld device Thanks to these protection codes the data can be downloaded only if those set on the handheld device coincide with those acquired previously by the vendin...

Page 34: ...TER OF NUMBER OF SALES PER LINE SALES PRICE To read the total absolute and partial since the last reset number of sales for each product price line GENERAL TOTAL NUMBER OF VENDING MACHINE SALES To read the general total number of vending machine sales GENERAL TOTAL VALUE OF VENDING MACHINE SALES To read the general total of the amount collected by the vending machine AUDIT DATA RESET To reset the ...

Page 35: ...menu see Motor anomaly messages chapter indicated above The indication remains until the out of order has been reset as indicated below Press the 4 key to cancel the Out of Service condition of the current motor The following message will appear on the display Press the 6 key to exit the submenu NOTE It is possible to cancel all of the Out of Order conditions of the motors without entering into pr...

Page 36: ...llation and service manual Problems and relative solutions chapter Motor anomaly messages section for the list of anomalies and relative solutions From these error conditions it is possible to make the check sequence continue by pressing the 3 key or end it with the 6 key One of the following messages will appear at the end of the check sequence This means that anomalies and or differences between...

Page 37: ...d Sliding Panel fully closed X 0 Micro switch not pressed Sliding Panel fully open or not fully closed L Locking lever product removal door Micro switch Y 1 Locking lever lowered product removal door Locked Y 0 Locking lever up product removal door Unlocked C Product removal door opening Micro switch K 1 Micro switch pressed product removal door Closed K 0 Micro switch not pressed product removal ...

Page 38: ... will be displayed see OFF message table for details When the following message appears on the display The following message will appear when the 3 key is pressed When the 3 key is pressed it will be possible to carry out a test delivery sale on the yy selection For each product delivered sold a beep will be emitted each time an object passes in front of the sensors and a different value will appe...

Page 39: ... code software Read only General Param s Software versions Displays software versions General Param s Default P Reset Card reinitialisation Password required General Param s Protected param Protected parameters Password required Reset Temp Reinitialise overtemperature times Price management Price A N xx Value of each of the 44 associable A bracket prices 0 635 35 2 00 Price management Price B enab...

Page 40: ... Param s Overtemper Time Overtemperature time 0 1440 min 30 Refrig Param s Refueling time Restocking time 0 1000 min 120 Refrig Param s Connected probes Number of connected refrigerator probes Read only EVA DTS parameters Reset passcode Reset Security and Passcode codes Password required Audit data Part Sale Numb Partial counter of number of vending machine sales Read only Audit data Part Sale Val...

Page 41: ...05 EN 61000 3 3 1995 A1 2001 A2 2005 EN 50366 2003 A1 2006 e soddisfa i requisiti essenziali della Direttiva 98 37 CE Declares that the machine described on the identification plate is in conformity with the legislative provisions of the following Directives 2006 95 CE and 2004 108 CE of the following regulations EN 60335 1 2002 A1 2004 A11 2004 A12 2006 EN 60335 2 75 2004 A1 2005 A11 2006 EN 5501...

Page 42: ... relative to the installation and connection of the device to the power supply systems are not included in the warranty either Damian S r l is not responsible for possible injuries and damage to persons or objects caused directly or indirectly by the lack of observance of the instructions given in this manual and of any other information transmitted by the manufacturer to the customer concerning a...

Page 43: ...Serie EUR7 Pagina A 25 Rev M 01 ...

Reviews: