14
Piranha 2 User’s Manual
03-032-00493-14
Teledyne DALSA
2.3 Connectors, Pinouts, and Cables
The cam era u ses a high -d ensity 26-p in MDR26 connector for Cam era Link control sign als,
d ata sign als, an d serial com m u nications, and a 6-p in H irose connector for p ow er.
Table 3: Camera Link Medium and Full Configuration
Medium and Full Configurations
Up to an additional 2 Channel Link Chips
Camera
Connector
Right Angle
Frame
Grabber
Channel
Link Signal
Cable Name
1
1
inner shield
Inner Shield
14
14
inner shield
Inner Shield
2
25
Y0-
PAIR1-
15
12
Y0+
PAIR1+
3
24
Y1-
PAIR2-
16
11
Y1+
PAIR2+
4
23
Y2-
PAIR3-
17
10
Y2+
PAIR3+
5
22
Yclk-
PAIR4-
18
9
Yclk+
PAIR4+
6
21
Y3-
PAIR5-
19
8
Y3+
PAIR5+
7
20
100 ohm
PAIR6+
20
7
term inated
PAIR6-
8
19
Z0-
PAIR7-
21
6
Z0+
PAIR7+
9
18
Z1-
PAIR8-
22
5
Z1+
PAIR8+
10
17
Z2-
PAIR9+
23
4
Z2+
PAIR9-
11
16
Zclk-
PAIR10-
24
3
Zclk+
12
15
Z3-
25
2
Z3+
PAIR11-
13
13
inner shield
Inner Shield
26
26
inner shield
Inner Shield
*Exterior Overshield is con nected to the shells of the connectors on both end s.
**3M p art 14X26-SZLB-XXX-0LC is a com p lete cable assem bly, inclu d ing connectors.
Base, Medium, and Full Configuration
Medium and Full Configuration Only
M
D
R
26 F
e
m
a
le
1
14
13
26
M
ating
P
art
: 3M
334-31 series
Cab
le:
3M
14X26-S
ZLB
-XXX-0LC
**