8
The Linea Color Camera
Flatness
y (parallelism)
x
y
z
z
50 µm
0.08° or 81 µm
± 300 µm
± 300 µm
± 300 µm
± 0.3°
Compliance
Regulatory Compliance
CE and RoHS, GenICam
*
F-mount lenses are optimized for a maximum image circle of 43.2 mm. The camera sensor is 57.67mm long.
Using an F-mount lens will generate a good image for the center 6008 pixels. However, pixels beyond this range
may suffer from optical distortion caused by the lens. If an application requires the use of an F-mount lens with
cameras, contact Customer Support for additional details regarding the use of F-mount lenses and for access to a
suitable F-mount-to-M72 adapter.
Operating ranges
Performance
Red
Green
Blue
Dynamic Range
63dB
63dB
63dB
Random Noise
2.72DN rms
2.72DN rms
2.72DN rms
Broadband Responsivity
See responsivity graph
Gain
1x to 10x Nominal Range (not including individual RGB gains for white balance)
DC Offset
<16DN
PRNU
<1.5%@50% Sat
FPN
5.6DN
SEE
11.1nJ/cm
2
13.3 nJ/cm
2
12.8 nJ/cm
2
NEE
7.55pJ/cm
2
9.00pJ/cm
2
8.77pJ/cm
2
Antiblooming
>100x Saturation
Integral non-linearity
<2%DN
All data quoted in 12 bit data format at 1x gain
Environmental Specifications
Environmental Specifications
Performance
Storage temperature range
-20 °C to +80 °C
Humidity (storage and operation)
15% to 85% relative, non-condensing
MTBF (mean time between failures)
>100,000 hours, typical field operation
Compliance, EMI Certifications
Compliance
EN 55011, FCC Part 15, CISPR 11, and ICES-003 Class A Radiated Emissions Requirements.
EN 55024, and EN 61326-1 Immunity to Disturbance.
RoHS per EU Directive 2002/95/EC and WEEE per EU Directive 2002/96/EC and China Electronic Industry
Standard SJ/T11364-2006
GenICam XML Description File, Superset of the GenICam™ Standard Features Naming Convention specification
V1.5, Camera Link Serial Communication: GenICam™ Generic Control Protocol (GenCP V1.0)