38
4. Camera Operation
Either the Factory or one of the User settings can be saved as the Default Setting by
selecting the set in the User Set Default Selector. The chosen set automatically saves as the
default setting and is the set loaded when the camera is reset or powered up.
The relationship between these three settings is illustrated in Figure 17. Relationship
between the Camera Settings:
Figure 17. Relationship between the Camera Settings
Active Settings for Current Session
The active setting for the current session is the set of configurations that are operating
while the camera is currently running, including all unsaved changes you have made to the
settings before saving them.
These active settings are stored in the camera‘s
volatile
memory and will be lost and cannot
be restored if the camera resets or if the camera is powered down or loses power.
To save these settings for reuse the next time you power up or reset the camera, or to
protect against losing them in the case of power loss, you must save the current settings
using the
User Set Save
parameter. Once saved, the current settings become the selected
User Set
.
User Setting
The user setting is the saved set of camera configurations that you can customize, resave,
and restore. By default the user settings are shipped with the same settings as the factory
set.
The command
User Set Save
saves the current settings to non-volatile memory as a
User
Set
. The camera automatically restores the last saved user settings when it powers up.