3.2 Battery safety and usage
Batteries should be stored in an ambient temperature of -4° F (–20° C) to
67.9° F (+20° C). Lithium batteries will self-discharge during storage, so they
should be fully charged before storage. Self-discharge may affect long term battery
performance. Furthermore, it is recommended that the battery should be charged in a
set time, as below;
Ambient temperature of:
●
-4° F (–20° C) to 67.9° F (+20° C), once every 6 months
●
67.9° F (+20° C) to 113° F (+45° C), once every 3 months
●
113° F (+45° C) to 149° F (+60° C), once every month
Battery should have greater than 50% charge prior to recharge.
The ambient temperature for charging should be 32° F (0° C) to 104° F
(+40° C). If under 32° F (0° C), the battery capacity will be diminished; if over
104° F (+40° C), the battery may overheat, resulting in permanent damage.
WARNING:
●
Never disassemble, incinerate or puncture battery
●
Never short circuit the battery
●
Keep battery dry
●
Keep out of reach of children
●
Always dispose of battery in accordance with local, state and federal regulations
3.3 Quick access
3.3.1 Capture an image
After installing the battery, press and hold the power key ( ≥ 3 seconds) until the
display comes on. After approximately 50 seconds, the power on routine will finish and
the camera will start its measurements.
Remove the lens cap and aim at the target. Adjust the focus for the clearest target
thermal image.
! Note:
Focus is not clear, and will lead to measurement error.