background image

DVX-1830 Series Sectional  

Installation Quick Guide

28 November 2016
DD3396953
Rev 00

201 Daktronics Drive Brookings SD 57006

800.325.8766

www.daktronics.com/support

Page 3 of 8

Side-to-Side Connection

1.  Connect the sections side to side before making any top-to-bottom 

connections.

2. 

Place the adjacent sections side by side so the alignment pyramids in each 

nest inside the corresponding recesses.

3.  Install 

1

/

4

″ bolts (located in the blue interconnect hardware bag) horizontally 

through all of the corner blocks in one cabinet and into the adjacent 

cabinet’s corresponding corner block’s nutsert (four per side). Refer to 

Figure 9 on page 3. Finger-tighten the bolts.

4.  Use a 

3

/

8

″ socket wrench to tighten the bolts. The minimum torque required 

is 6 ft-lbs. Avoid over-tightening. After the corner blocks are tight together, 

additional torque will not tighten the seams and can damage the blocks.

5.  Inspect the corner blocks on the installed section visually to ensure the faces 

shown in 

Figure 4 on page 2 and Figure 5 on page 2

 are flush and 

aligned.

6. 

Use a 4′ level to ensure the display faces are flush and flat to all adjacent 

sections. Refer to Figure 6 on page 2.

Top-to-Bottom Connection

1.  Connect the sections side to side before making any top-to-bottom 

connections.

2. 

Place the adjacent sections on top of each other so the alignment pyramids 

of each nest inside the corresponding recesses.

3.  Install 

1

/

4

″ bolts (located in the blue interconnect hardware bag) vertically 

through all of the corner blocks in one cabinet and into the adjacent 

cabinet’s corresponding corner block’s nutsert (four per side). Refer to 

Figure 10 on page 3. Finger-tighten the bolts.

4.  Use a 

3

/

8

″ socket wrench to tighten the bolts. The minimum torque required is 

6 ft-lbs. Avoid over-tightening. After the corner blocks are tight together, additional torque will not tighten 

the seams and can damage the blocks.

5. 

Inspect the corner blocks on the installed section visually to ensure the faces shown in 

Figure 4 on page 

2 and Figure 5 on page 2

 are flush and aligned.

6. 

Use a 4′ level (when possible) to ensure the display faces are flush and flat to all adjacent sections. See 

Figure 6 on page 2.

Figure 9: 

Installing Bolt through 

Corner Block

Figure 10: 

Installing Bolt through 

Corner Block

Summary of Contents for DVX-1830 Series

Page 1: ...ermanently attaching to the structure Refer to Figure 2 on page 1 for connection details 4 Secure the section until it is permanently attached to the structure using only one of the two methods descri...

Page 2: ...cent sections Refer to Figure 6 on page 2 If they are no longer aligned loosen the section interconnect hardware and repeat Steps 4 7 8 Attach the clips to the structure by either welding or installin...

Page 3: ...flush and aligned 6 Use a 4 level to ensure the display faces are flush and flat to all adjacent sections Refer to Figure 6 on page 2 Top to Bottom Connection 1 Connect the sections side to side befor...

Page 4: ...tions in the bottom of the top cabinet or the left side of the right cabinet and into the next cabinet s nutsert Tighten these bolts until the seam is within tolerance Refer to the DD3008872 DVX 11X2...

Page 5: ...e 15 on page 5 and the Signal Interconnect Drawing and System Riser Diagram Fiber SATA Power Ethernet Term Panel Input Quick Connect Prolink Router Power Entrance TP IQC PLR PE Digital Media Player Fi...

Page 6: ...Drawing for routing information 5 Route the coiled power cables from section to section connecting to the power harness in the next section Refer to the Signal Interconnect Drawing Note The fiber pow...

Page 7: ...nduits should point downward or have a fitting attached to prevent water from entering the conduit GND Alternate power and signal entrance Power in Fiber out Power and signal entrance remove hole seal...

Page 8: ...he proper quick connect jacks on the rear of the display as necessary Verify the caps on the jacks are properly installed if the jacks are not in use Figure 27 Quick Connect Jacks ETHERNET IN J33 J35...

Reviews: