DVX-1830 Series Sectional  

Installation Quick Guide

28 November 2016
DD3396953
Rev 00

201 Daktronics Drive Brookings SD 57006

800.325.8766

www.daktronics.com/support

Page 7 of 8

6. 

Route the power cables through conduit to the termination panels inside the display at the sections 

specified on the shop drawing.

7.  Connect ground electrode from earth ground rod to the ground lug on the rear of 

each display face.

8.  Test the display ground to ensure it has a resistance-to-ground of 10 ohms or less.

Optional Conduit Whip

Refer to the System Riser Diagram to verify where conduit whips should route. If a conduit 

whip is installed, the internal cabinet power connections will already be made.

Note: 

This display allows water to enter, 

so incoming conduits should point 

downward or have a fitting attached to 

prevent water from entering the conduit.

GND

Alternate power and

signal entrance

Power in

Fiber out

Power and signal

entrance (remove

hole seal if needed)

Field termination location

Service Ground

Maximum wire size = 6 AWG

Minimum wire size = 14 AWG

Figure 22: 

Power Entrance (Rear View)

WARNING

AVERTISSEMENT

120V AC

BEHIND THIS PANEL

CB 1

CB 2

20

20

20

20

LINE

LOAD

WARNING

AVERTISSEMENT

120V AC

BEHIND THIS PANEL

20

CB 1

CB 2

20A

ON ON

BREAKERS PROVIDE

SUPPLEMENTARY

PROTECTION ONLY.

LINE

LOAD

20A

20A

ON ON N L

120V Branch

120BR

240V Branch

240BR

Figure 23: 

Power Termination Panels

Figure 24: 

Ground Lug

Remove screws

and brackets to

release conduit

whip for routing.

Brackets are

unnecessary after

installation and

may be disposed.

Figure 25: 

Conduit Whip

Neutral: white

or blue
Ground: green

and yellow

Line: black

or brown

Figure 26: 

Conduit End with Wire to Terminate to 

Junction Box

Summary of Contents for DVX-1830 Series

Page 1: ...ermanently attaching to the structure Refer to Figure 2 on page 1 for connection details 4 Secure the section until it is permanently attached to the structure using only one of the two methods descri...

Page 2: ...cent sections Refer to Figure 6 on page 2 If they are no longer aligned loosen the section interconnect hardware and repeat Steps 4 7 8 Attach the clips to the structure by either welding or installin...

Page 3: ...flush and aligned 6 Use a 4 level to ensure the display faces are flush and flat to all adjacent sections Refer to Figure 6 on page 2 Top to Bottom Connection 1 Connect the sections side to side befor...

Page 4: ...tions in the bottom of the top cabinet or the left side of the right cabinet and into the next cabinet s nutsert Tighten these bolts until the seam is within tolerance Refer to the DD3008872 DVX 11X2...

Page 5: ...e 15 on page 5 and the Signal Interconnect Drawing and System Riser Diagram Fiber SATA Power Ethernet Term Panel Input Quick Connect Prolink Router Power Entrance TP IQC PLR PE Digital Media Player Fi...

Page 6: ...Drawing for routing information 5 Route the coiled power cables from section to section connecting to the power harness in the next section Refer to the Signal Interconnect Drawing Note The fiber pow...

Page 7: ...nduits should point downward or have a fitting attached to prevent water from entering the conduit GND Alternate power and signal entrance Power in Fiber out Power and signal entrance remove hole seal...

Page 8: ...he proper quick connect jacks on the rear of the display as necessary Verify the caps on the jacks are properly installed if the jacks are not in use Figure 27 Quick Connect Jacks ETHERNET IN J33 J35...