It is possible to manage hardwired system
arming/disarming using wireless control devices
(remote controls and keypads) and a specific output
if the control panel is fitted with an input. To adapt this command,
the closed or open status of the relay can be associated with the disarmed
status (OFF on control devices).
214
GB
5.8.1 Disconnected with relay closed (OFF = closed)
In this configuration, the receiver changes the status of the closed relay on receipt of the OFF
command sent by the control devices.
5.8.2 Disconnected with relay open (OFF = open)
In this configuration, the receiver changes the status of the open relay on receipt of the OFF
command sent by the control devices.
Connection relay operation can be changed via the “Programming” menu and the “Conn. Relay”
sub-menu in “Installation” mode.
Example:
to change connection relay operation so that the contact is open and not closed.
1.
Select the menu as shown below in order to identify the relay to be changed:
Installing mode
>
Programming
Programming
>
Arm Output
5.8 Operating modes for control panel arm/disarm relay (RAC)
5.9 Changing control panel arm/disarm relay operation
IMPORTANT: the relay is factory-programmed with its closed status corresponding to the OFF
command sent by the control devices.
IMPORTANT: the Connection output is factory-programmed for “OFF = closed” (relay contact
closed on receipt of disarm/OFF command).
OK
Installing mode
>
Programming
t
Programming
>
Language select
t
t
t
Programming
>
Recognition
Programming
>
Zone Outputs
Programming
>
Tamper Output
t
Programming
>
Fault Ouput
OK
Programming
>
Arm Output
Arm Output
OFF = Closed