206
GB
This function is useful at the end of installation operations for checking
the list of recognised products. To check the list of recognised detectors,
go to the “Recognit. check”.
Select the menu as shown below:
Installing mode
>
Programming
Installing mode
>
Recognit. check
In this example, the recognition programming checking procedure shows that only two zones
have been configured for the receiver: detector n° 1 and n° 2 have been programmed for
recognition in zone 1 while detector n° 3 has been programmed for recognition in zone 2.v
5.
Press the
OK
button. The screen displays:
6.
Appuyer sur le bouton
t
pour sélectionner la sortie du menu.
Control recog.
>
Auto-recognition
Example:
list of zones configured and detectors recognised.
Make a note of
the recognition
programming
performed on the
installation sheet at the
back of this manual.
4.3 Checking recognition programming
IMPORTANT
• The only zones displayed are those with at least one recognised detector.
• The receiver does not have recognition programming checking functions for the remote
controls.
• Products are automatically numbered by the receiver, in chronological order of recognition
programming.
t
Installing mode
>
Programming
OK
Installing mode
>
Recognit. check
OK
Recognit. check
>
Zone 1
t
Zone 1
Detector
01
t
Zone 1
Detector
02
OK
Zone 1
< Exit
t
Recognit. check
>
Zone 1
OK
Recognit. check
>
Zone 2
t
Zone 2
Detector
03
OK
Zone 2
< Exit
t
Recognit. check
>
Zone 2
OK
Recognit. check
< Exit
OK
Installing mode
>
Recognit. check
Summary of Contents for 785-21X