![Dairy Tech Perfect Udder Owner'S Manual Download Page 29](http://html1.mh-extra.com/html/dairy-tech/perfect-udder/perfect-udder_owners-manual_3224906029.webp)
27
Perfect Udder® Bag PASTEURIZER/WARMER Owner Manual
revJUNE2016
TROUBLESHOOTING THE BAG
WARMER
D10 Temperature Control
• This guide is intended for use as a
troubleshooting directive. All electrical tests
and diagnostics should be performed only
by those skilled in the electrical profession
• All electrical testing and repairs should be
performed by an experienced professional
or technician trained in the electrical trade
• Serious injury or death may result from
improperly testing or handling this
equipment
• This unit contains HIGH VOLTAGE electricity
that can cause serious harm or death
The Perfect Udder® BAG Warmer contains the D10
Temperature Controller. This unit is intended to control the
temperature of the water bath during the “Ready State” as
well as during the “Heating State”. This allows the unit to be
ready with a large heat sink for rapid warming of colostrum.
Seen from the front of the machine just above the timer knob,
the D10-Front is located behind the red transparent plastic. In
the rare event you need access to this control, gently push in
on the sides of the red plastic part while lifting to free it from
the holding tabs.
To access the control for setting adjustments, hold in the M
button for 5 seconds to display the function screens. Press
the S button to see the value for that function and then the
UP and DOWN arrows to make adjustments to that function.
To save a setting, press the S button again to return to the
Function display.
The following is a list of the normal parameter settings for the
D10 control
F11
Set Point Temperature = 118°F (47.7°C)
F12
Temperature Difference = 1°
F13
Max Temperature = 180°F (82°C)
F14
Min Temperature = 35°F (2°C)
F19
Calibration Difference Between Test Thermometer
and Display
(measured near 125°)
F21
Compressor Delay Time = 0.00
F29
Temp Mode = HEAT
F50
Ext alarm mode = 0
F80
password = OFF
F81
Temperature Units = F or C
F98
Reserved = Do Not Touch
F99
Self Test = Do Not Use This Function When
Controler is Running
END Exit
M Button = to Exit the Control
M Button = can also be used to cancel when in the process
of setting a parameter.
POSSIBLE ERROR MESSAGES
A21
flashing “SHr” means temp sensor is shorted out
and must be replaced.
A21
flashing “OPE” means the temp sensor is either;
broken, disconnected or damaged and may need
replaced.
M
S
Up
Down