![Dairy Tech Perfect Udder Owner'S Manual Download Page 21](http://html1.mh-extra.com/html/dairy-tech/perfect-udder/perfect-udder_owners-manual_3224906021.webp)
19
Perfect Udder® Bag PASTEURIZER/WARMER Owner Manual
revJUNE2016
TO STORE
Selecting the “
To Store
” Pasteurization Option allows you
to pasteurize, then cool colostrum to be stored in the
refrigerator or the freezer. This profile is recommended for use
with Perfect Udder® Bags.
A screen will show all the parameters of the last “TO STORE”
program ran.
XX.XX °F
00/00/00
18:00
PASTEURIZE TO STORE
START
ADJUST
PASTEURIZE TEMPERATURE
140.0 °F
DWELL TIME
60:00:00 H:M:S
110.0°F
75.0°F
75.0
°F
COOL TEMPERATURE
You have 3 choices: BACK, ADJUST or START
1.
Press “
BACK
” button and return to the
“Pasteurize” menu to select from one of the other
3 options
2.
ADJUST
Press “
ADJUST
” to change the current
settings.
Adjusting Program Settings
Pressing the “ADJUST” button will highlight all available
adjustments that can be made to the current program.
A BLUE BOX will indicate the current active fields to be
adjusted.
XX.XX °F
00/00/00
18:00
PASTEURIZE TO STORE
START
ADJUST
PASTEURIZE TEMPERATURE
140.0 °F
DWELL TIME
60:00:00 H:M:S
110.0°F
75.0°F
75.0 °F
COOL TEMPERATURE
Use the arrow buttons to adjust the
setting in the active BLUE BOX up or down.
To activate a different field, simply touch it and it will turn
BLUE to indicate that it is now active.
XX.XX °F
00/00/00
18:00
PASTEURIZE TO STORE
START
ADJUST
PASTEURIZE TEMPERATURE
140.0 °F
DWELL TIME
60:00:00 H:M:S
110.0°F
75.0°F
75.0 °F
COOL TEMPERATURE
3.
START
When you are satisfied with your
adjustments, press “
START
” to begin the
program.
Once the program is in progress, the screen will indicate
which stage the program is in.
XX.XX °F
00/00/00
18:00
PASTEURIZE TO STORE
CURRENT TEMP 110°F
Cooling to 60°F
Upon completion, the Controller Screen will indicate
“COMPLETE”.
XX.XX °F
00/00/00
18:00
PASTEURIZE TO STORE
PROGRAM COMPLETE
Pressing the “HOME” button will take the operator