background image

Tetra

®

 PowerStrip DS

Installation Guide

3

Power 

Supply

To LED System

Red (+)

Black or blue (-)

Run a wire from the power supply to inside the sign 

and connect to the first module on the strip. 
NOTE: Exceeding maximum load will cause the power 

supply to shut down. If overload occurs, remove excess 

load, recycle the input power to restart the power supply.

Connect the red stripe wire (+) of the LED system to 

the red wire (+) of the power supply. Connect the white 

wire (-) of the LED system to the black or blue wire (-) 

of the power supply.

Connect modules using twist-on wire connectors or 

in-line (IDC) connectors. Join white wires together 

and red striped wires together. 
NOTE: Additional supply wire may be necessary to 

bridge electrical connections.

Cap all exposed wires with appropriate end caps 

or apply electric grade (non-corrosive) silicone for 

additional weather protection.

Electrical Connections

Red stripe (+)

White (-)

To Power Supply 

Red (+)

Red stripe (+)

White (-)

Black or blue (-) 

NOTE: Do not use connectors pre-filled with silicone grease/mineral base protective grease or use silicone grease to seal connections.

NOTE: All electrical connections should be suitably 

protected from mechanical damage and the 

environment. Seal all connections in locations that may 

be exposed to water with electrical grade RTV silicone.

1

3

2

4

Retrofit Instructions

1.   (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the building.  Ensure 

that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power supply, and have a current 

rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes (whichever is less).   

2.   (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or fluorescent tubes; and associated transformers 

and ballasts.  Care should be taken not to break the existing neon or fluorescent tubes. 

NOTE: Follow all federal and local regulations when disposing of neon tubing, fluorescent tubes, transformers and ballasts.

3.   (Existing Signs Only)  If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable local, state, or country 

electrical codes; a new disconnect switch must be installed.

4.   (Existing Signs Only) Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm (1/2-in) diameter require a 

metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed with non-hardening caulk.

5.  Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
6.  A Tetra

®

 24VDC Class 2 Power Supply, as listed below, must be used with this retrofit kit.  Using the Maximum Loading chart below, determine the 

number of Tetra

®

 Class 2 Power Supplies required to power the number of LED modules required to illuminate the sign, so as not to overload the 

Tetra

®

 Class 2 Power Supply chosen.

7.  Follow the instructions above to properly mount the LED modules. 
8.  Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.
9.  Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions found in the  

 

power supply installation guide.

10.  If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable  local, state, and country electrical codes.

Summary of Contents for GE current Tetra PowerStrip DS

Page 1: ...the installation instructions and where the input rating of the retrofit kit does not exceed the input rating of the sign Installation of this LED retrofit kit may involve drilling or punching of hol...

Page 2: ...certified 18 AWG 0 82 mm2 supply wire or approved equivalent UL certified 22 14 AWG 0 33 2 08 mm2 wire connectors or 18 14 AWG 0 82 2 08 mm2 inline IDC connectors or approved equivalent 6 x 75 inch M3...

Page 3: ...ed by applicable local state or country electrical codes whichever is less 2 Existing Signs Only Remove the existing lighting equipment to be replaced such as neon tubing or fluorescent tubes and asso...

Page 4: ...ximum load Ensure the length and gauge of the supply wire is equal to or below the recommended remote mounting distance 18 AWG 0 82 mm2 Supply Wire 16 AWG 1 31 mm2 Supply Wire 14 AWG 2 08 mm2 Supply W...

Page 5: ...e leuchten schwach Sicherstellen dass die Gesamtl nge des Tetra LED Systems die maximale Last nicht berschreitet Sicherstellen dass die L nge und die Drahtst rke des Stromversorgungskabels der empfohl...

Page 6: ...systeem de maximale belasting niet overschrijdt Individuele modules geven geen licht Verwijder de module en vervang deze door een werkende module Modules geven slecht licht Zorg dat de totale lengte...

Page 7: ...entation Tetra 24 V CC de classe 2 HU Elhelyez si javaslatok A t bla m lys ge Sorok k z tti t vols g MEGJEGYZ S A javasolt minim lis t blam lys g 10 h velyk 254 mm Felszerel s T bla s nekkel 1 M rje l...

Page 8: ...ikacijos Did iausia vieno Tetra 24 VDC 2 klas s maitinimo altinio apkrova NO Layoutanbefalinger Skiltdybde Radavstand OBS Minste anbefalte skiltdybde er 254 mm 10 tommer Installasjon Skilt med skinner...

Page 9: ...h dla monta u odleg ego Specyfikacje Maksymalne warto ci obci e dla zasilacza Tetra 24 VDC Class 2 Power Supply PO Recomenda es para a Disposi o Profundidade do letreiro Espa amento entre filas ATEN O...

Page 10: ...de que la longitud total del sistema Tetra LED no excede la carga m xima Aseg rese de que la longitud y calibre del cable de alimentaci n es igual o inferior a distancia recomendada de montaje remoto...

Page 11: ...cendono Rimuovere il modulo e sostituirlo con un modulo funzionante La luce dei moduli fioca Assicurarsi che la lunghezza complessiva del sistema a LED Tetra non superi il carico massimo Assicurarsi c...

Page 12: ...eserved GE and the GE monogram are trademarks of the General Electric Company and are used under license Information provided is subject to change without notice All values are design or typical value...

Reviews: