2
5
• HRV • VKM-GA(M)V1
• HRV
•
Heat Reclaim Ventilation
158
5.3.3
Efficient Outdoor Air Introduction with Heat Exchanger and Cooling / Heating Operation
Indoor unit with outdoor air treatment
Using outdoor air, the temperature can
be brought near room temperature with
minimal cooling capacity through the
use of outdoor air.
5.3.4
Operations, Such as Cleaning, Ventilation, Cooling / Heating and Humidifying, are Possible
with One Remote Controller.
Four air conditioner functions can be managed using a single remote control. This makes it easy to obtain
high-quality and energy-efficient outdoor air treatment.
5.4
Unique Control System
5.4.1
Independent Control Possible
Individual outdoor air treatment operation is
possible by connecting an optional remote
controller.
5.5
Quiet Operation
Reduced pressure loss and quieter operation internally lowers the noise output of the 1,000m
3
/h type
system to 38dB (VKM100GAMV1 at 50Hz 240V, High mode).
5.6
Easy Installation
5.6.1
Integrated System Includes Ventilation, Air Conditioning and Humidifying Operations
Rather than using separate ventilation, air conditioning, and humidifying components, the system
incorporating HRV (VKM) integrates all functions, reducing the total number of indoor units and facilitating
a far simpler system. The installation space becomes smaller and the labor required for installation and
Heating and cooling
+
+
heat recovery
humidifying
–5
0
5
10
15
20
Dry bulb temperature (˚CDB)
25
30
35
40
Relativ
e humidity (%)
20
40
60
80
100
Effect of full heat exchange
Effect of full heat exchange
Effect of full heat exchange
Effect of cooling
Outdoor air temperature
in summer
Indoor temperature during heating
Indoor temperature during cooling
Outdoor air temperature
in winter
Effect of heating
Effect of heating
Effect of
humidification
The VRV
III
outdoor unit
Indoor unit
remote control
Link connection
Control of the HRV (VKM) type indoor unit is managed using
the remote control of the standard indoor units connected.
During group control operation, the unit has a capacity
equivalent to two standard indoor units. Up to 16 standard
indoor units can be connected at once.
HRV (VKM)
The VRV
III
outdoor unit
Indoor unit
remote control
HRV (VKM)
HRV (VKM)
HRV (VKM)
Summary of Contents for VAM-FA8VE
Page 1: ...EEDEN07 201 technical data heat reclaim ventilation VAM FA8VE VKM GAMV1 VKM GAV1 ...
Page 2: ......
Page 152: ......
Page 272: ...2 11 270 HRV VKM GA M V1 HRV Heat Reclaim Ventilation Length Flow rate ...
Page 275: ...2 11 HRV VKM GA M V1 HRV Heat Reclaim Ventilation 273 Temperature conversion table ...