PIM00424
12-6
Please confirm the corresponding column in the "
■■■■■
" in SUT
●●■■■■■
-30 for the mode code of your
product.
■
Table 1: PQ setting list
Product Type
(
SUT
●●■■■■■
-30
)
Name
S8007 D8021
The default value
3.5
Range
[MPa]
1.5
〜
20.6
The default value
51
High-pressure side
pressure setting
Range
[×10PSI]
22
〜
298
The default value
1.5 1.5
Range
[MPa]
1.5
〜
7.0 1.5
〜
7.0
The default value
22 51
Low-pressure side
pressure setting
Range
[×10PSI]
22
〜
101 22
〜
101
The default value
15.0
High-pressure side
flow rate setting
Range
[L/min]
4.0
〜
30.0
The default value
83.0
Low-pressure side
flow rate setting
Range
[L/min]
11.6
〜
83.0
The default value
0.1
Acceleration time
setting
Range
[sec/MPa]
[sec/1000min
-1
]
0.01
〜
99.99
The default value
0.1
Deceleration time
setting
Range
[sec/MPa]
[sec/1000min
-1
]
0.01
〜
99.99
CAUTION
The standard factory setting of "P04: Pressure unit select setting" is MPa.
When it was changed to PSI display, please adhere a seal to make it understand easy. Please prepare the display
seal. However, If it is used in Japan, you will be punished by the Measurement Law.
Summary of Contents for Super Unit SUT00S8007-30
Page 2: ......
Page 12: ......
Page 19: ...PIM00424 3 5 3 4 Dimensions Motor Pump Type SUT00 SUT00S8007 30 ...
Page 20: ...PIM00424 3 6 SUT00D8021 30 ...
Page 21: ...PIM00424 3 7 Unit Type SUT10 SUT16 SUT10S8007 30 ...
Page 22: ...PIM00424 3 8 SUT10D8021 30 ...
Page 23: ...PIM00424 3 9 SUT16D8021 30 ...
Page 28: ......
Page 32: ......
Page 34: ......
Page 38: ......
Page 42: ......
Page 50: ......
Page 60: ......
Page 92: ......